Abstract:In this paper, it analyzes the mathematical model of three-phase PWM converter under unbalanced grid voltage. Basing on the mathematical model, a novel negative sequence current control strategy of three-phase voltage source PWM converter under unbalance grid is proposed. The novel strategy uses a novel PLL technique to detect the positive and negative sequence of unbalance grid. Negative current closed-loop control strategy is used in the novel strategy to decrease the negative component in the grid current. Finally, the simulation verified the correctness and rationality of the proposed method.
张一彦, 陆贤锋, 秦青峰. 电网电压不平衡时PWM变流器负序电流控制策略研究[J]. 电气技术, 2015, 16(8): 19-24.
Zhang Yiyan, Lu Xianfeng, Qin Qingfeng. Research on Negative Current Control Strategy of Three-phase PWM Converter under Unbalance Grid Voltage. Electrical Engineering, 2015, 16(8): 19-24.
[1] 谭广军. 电网不平衡条件下PWM整流器控制技术研究[D]. 哈尔滨: 哈尔滨工业大学, 2008. [2] 黄泳均. 电网不平衡下三相PWM整流器的控制策略研究[D]. 北京: 北京交通大学, 2009. [3] 刘永生. 电网电压不平衡时PWM整流器控制策略研究[D]. 成都: 西南交通大学, 2011. [4] Rioual P, Pouliquen H, Louis J P. Regulation of a PWM rectifier in the unbalanced network state using a generalized model[J]. IEEE Transactions on Power Electronics, 1996, 11(3): 495-502. [5] Stankovic A V, Lipo T A. A novel control method for input output harmonic elimination of the PWM boost type rectifier under unbalanced operating conditions[J]. IEEE Transactions on Power Electronics, 2001, 16(5): 603-611. [6] Yuan Xiaoming, Merk W, Stemmler H, et al. Stationary-frame generalized integrators for current harmonics of concern under unbalanced and distorted operating conditions[J]. IEEE Transactions on Industry Applications, 2002, 38(2): 523-532. [7] Etxeberria-Otadui I, Viscarret U, Caballero MA, et al. New optimized PWM VSC control structures and strategies under unbalanced voltage transients[J]. IEEE Transactions on Industrial Electronics, 2007, 54(5): 2902-2914. [8] Hu Jiabing, He Yikang, Xu Lie, et al. Improved control of DFIG systems during network unbalance using PI-R current regulators[J]. IEEE Transactions on Industrial Electronics, 2009, 56(2): 439-451. [9] Roiu D, Bojoi R I, Limongi R I, et al. New stationary flame control scheme for three-phase PWM rectifiers under unbalanced voltage dips conditions[J]. IEEE Transactions on Industry Applications, 2010, 46(1): 268-277. [10] 周鹏, 贺益康, 胡家兵. 电网不平衡状态下风电机组运行控制中电压同步信号的检测[J]. 电工技术学报, 2008, 23(5): 108-113. [11] Moran L, Ziogas P D, Joos G. Design aspects of synchronous PWM rectifier-inverter systems under unbalanced input voltage conditions[J]. IEEE Transactions on Industry Applications, 1992, 28(6): 1283-1286. [12] GB/T 15543—2008. 电能质量三相电压不平衡[S].北京: 中国标准出版社, 2008. [13] Vincenti D, Jin H. A three phase regulated PWM rectifier with on-line feed-forward input unbalance correction[J]. IEEE Transactions on Industrial Electronics, 1994(41): 526-532. [14] Song H S, Nam K. Dual current control scheme for PWM converter under unbalanced input voltage conditions[J]. IEEE Transactions on Industrial Electronics, 1999, 46(5): 953-959. [15] Xu L, Andersen L R, Cartwright P. VSC transmission operating under unbalanced AC conditions-Analysis and control design[J]. IEEE Transactions on Power Delivery, 2005, 20(1): 427-434.