Abstract:According to the real-time and accuracy requirements of the signal harmonic frequency measurement, this article analyzed the basic principles of the fixed interval sampling frequency measurement algorithm, and clarified the limitation of fixed interval sampling frequency measurement algorithem. Then, this paper proposd an improved method to solve the real-time disadvantage of existing algorithms. Finally, the implementation is verified on the DC merging unit.