Abstract:For AP1000 passive nuclear power units island operation mode, according to the characteristics of SEL-351 relay and the analysis to the technical difficulties in the process of plant service supplies transition, demonstrates the feasibility of plant service supplies transfer in checking the synchronizing parameters and compares the advantages and disadvantages of the transfer schemes, then propounds a plant service supplies transfer scheme with combination of parallel transfer and fast transfer. This transfer doesn't cause losing the plant service supplies and costs little operation time, and will provide instruction for development a plan of plant service supplies transfer in island operation mode.
任少义, 石康宁, 李彪, 李忠全. AP1000核电厂孤岛运行厂用电源同期切换研究[J]. 电气技术, 2017, 18(9): 57-60.
Ren Shaoyi, Shi Kangning, Li Biao, Li Zhongquan. Study on AP1000 Nuclear Power Plant Service Supplies Synchronizing Transfer in Island Operation Mode. Electrical Engineering, 2017, 18(9): 57-60.