Abstract Fault line Selection in Non-Effective Earthed System is an important subject that need to be solved urgently under construction, rebuilding of the power distribution system. The thesis summarizing the existing line selection, from three angle of view including a single criterion fault line selection method, basing the information fusion fault line selection method and referencing the theory of other disciplines and location method launches review. And combined with domestic and international relevant research literature, developing the line selection method development
|
|
|
|
|
Cite this article: |
Xiong Tingting,Zeng Xiangjun,Wang Yuanyuan等. Review of Earth Fault Feeder Detection Technology in Neutral Ineffectively Earthed Power Systems[J]. Electrical Engineering, 2013, 14(5): 1-6.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2013/V14/I5/1
|
[1] 沈晓凡, 舒治淮. 2008年国家电网公司机电保护装置运行情况[J].电网技术, 2010, 34(3):173-177. [2] 杨以涵, 李砚.小电流接地电网单相接地故障选线研究路线?方法?成果[C].全国电网中性点接地方式与接地技术研讨会论文集, 中国杭州, 2005:149-157. [3] 张尔桦, 潘贞存, 桑在中, 杨喃喃. 群体比幅原理接地选线保护[J].中国电力, 1993(11):15-17. [4] 张慧芬, 潘贞存, 田质广.基于可辨识矩阵的单相接地故障选线新方法[J].中国电力, 2006, 39(11):33-36. [5] 牟龙华.零序电流有功分量方向接地选线保护原理[J].电网技术, 1999, 23(9):60-62. [6] 檀国彪, 涂东明, 陈大鹏. 基于最大Isinψ或△(Isinψ)原理的微机选线装置[J].中国电力, 1995(7):16-20. [7] 曾祥君, 尹项根, 陈德树.适应配电自动化的馈线接地保护研究[J].电力系统自动化, 2000, 24(15):37-41. [8] 张彦昌, 吕艳萍, 李振强, 董培.扩展Prony谐波分析法在配电网接地选线中的应用[J].电气应用, 2007, 26(5): 33-37. [9] 张仲孝, 苗世洪, 林湘宁, 刘沛.基于多孔算法的小电流接地系统故障选线算法[J].电力系统自动化, 2011, 35(1): 66-70. [10] 杨丽娜, 周敏.改进希尔伯特黄变换理论在配电网故障选线中的应用与研究[J].东北电力大学学报, 2011, 31(2):44-48. [11] 张钧, 何正友, 贾勇.基于S变换的故障选线新方法[J].中国电机工程学报, 2011, 31(10):109-115. [12] 张大波, 刘志刚.基于相差统计的小电流单相接地选线新判据[J].电力系统自动化, 2007, 31(11):77-80. [13] 桑在中, 潘贞存, 李磊.“ S注入法”与选线测距定位[J].电力系统及其自动化学报, 1998(4):35-39. [14] 曾祥君, 尹项根, 于永源, 等.基于注入变频信号法的经消弧线圈接地系统控制与保护新方法[J].中国电机工程学报, 2000, 20(1):29-36. [15] 齐郑, 艾欣. 基于粗糙集理论的小电流接地系统故障选线方法的有效域[J].电网技术, 2005, 29(12): 43-46. [16] 庞清乐, 孙同景, 穆健, 秦伟刚.基于神经网络的中性点经消弧线圈接地系统故障选线方法[J].电网技术, 2005, 29(24):78-81. [17] 张世标.电力系统输电线路单相接地故障选线与测距[D].天津大学, 2008. [18] 房鑫炎, 郁惟镛, 庄伟.模糊神经网络在小电流接地系统选线中的应用[J].电网技术, 2002, 26(5):16-19. [19] 庞清乐, 孙同景.基于蚁群算法的神经网络配电网故障选线方法[J].继电器, 2007, 35(16):1-6. [20] 张海平, 何正友, 张钧.基于量子神经网络和证据融合的小电流接地选线方法[J].电工技术学报, 2009, 24(12): 171-178. [21] 陈炯聪, 齐郑, 杨奇逊.基于模糊理论的小电流单相接地选线装置[J].电力系统自动化, 2004, 28(8):88-91. [22] 张钧, 何正友, 贾勇.基于S变换的故障选线新方法[J].中国电机工程学报, 2011, 31(10):109-115. [23] 李玲玲, 李凤强, 王成山.基于模糊综合决策的配电网单相接地故障选线[J].电力系统及其自动化学报, 2011, 23(5):43-46. [24] 徐岩, 刘金生.基于模糊聚类理论的电网故障元件定位[J].电网技术, 2010, 34(8):188-193. [25] WANG Y Y, JIAN J B, ZENG X J, LONG L H. Grounding faulted feeder detection based on fuzzy clustering algorithms[J]. Applied Mechanics and Materials, 2011, 2:989-994. [26] WANG Y Y, JIAN J B, ZENG X J, LONG L H. Grounding faulted feeder protection in neutral noneffectively grounded distribution system based on hierarchical clustering technique[C]. The International Conference on Advanced Power System Automation and Protection (APAP2011) Beijing China, 2011:16-20. [27] 毛鹏, 段玉倩, 姜娜.基于相关分析的故障选线方法[J].电网技术, 2004, 28(2):36-39. [28] 束洪春, 徐亮.谐振接地电网故障选线相关分析法[J].电力自动化设备, 2008, 28(9):6-9. [29] 梁睿, 王崇林.基于灰色关联的小电流接地选线研究[J].电力系统保护与控制, 2009, 37(7):17-21. [30] 任建文, 孙文武.基于数学形态学的配电网单相接地故障暂态选线算法[J].电力系统自动化, 2008, 32(1): 70-75. [31] 李天云, 祝磊.基于数学形态谱的配电网接地选线新方法[J].电力自动化设备, 2009, 29(2):35-38. |
|
|
|