Setting and Coordination of Voltage Compensative Ratio for Different Connection Mode |
Chen Yanyun1,Cai Pei1,Wang Rui2,Dai Shenhua3 |
1. Guodian Science and Technology Research Institute,Nanjing 210031; 2. Army Officer Academic,Hefei 230031; 3. Anhui Electric Power Research Institute,Hefei 230601 |
|
|
Abstract Aiming at the problem of voltage compensative ratio setting and coordination for large generator,combined with the principle,this paper provides the method and consideration of setting voltage compensative ratio in detail for both the generator-transformer unit wiring mode and the three winding transformer parallel mode. With concrete examples,the setting and coordination method is verified to be feasible.
|
Received: 22 January 2015
Published: 19 January 2015
|
|
|
|
Cite this article: |
Chen Yanyun,Cai Pei,Wang Rui等. Setting and Coordination of Voltage Compensative Ratio for Different Connection Mode[J]. Electrical Engineering, 2015, 16(01): 71-74.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2015/V16/I01/71
|
[1] 竺士章. 发电机励磁系统试验[M]. 北京: 中国电力出版社,2005. [2] 刘取. 电力系统稳定性及发电机励磁控制[M]. 北京:中国电力出版社,2007. [3] 方思立,苏为民. 大型发电机调差率整定及调试[J].中国电力,2006,39(8): 12-15. [4] 张宁,李海翔. 同步发电机组电压调差系数实用整定方法研究[J]. 浙江电力,1996,15(5): 6-9. [5] 陈继武. 励磁调节器中的调差问题[J]. 华东电力,2002,(10): 35-36. [6] DL/T 843—2010 大型汽轮发电机励磁系统技术条件[S]. [7] 郭玉恒,徐学琴. 机组并网瞬间抢无功现象分析及定值整定策略[J]. 水电自动化与大坝监测,2011,35(3): 21-24. |
|
|
|