Aging Condition Evaluation of Oil-Paper Insulation based on Depolarization Current Sub-lines |
Wu Wenxuan1, 3, Zhang Konglin2, 3, Cai Jinding3, Shi Guangyu2, Li Anna3 |
1. Sate Grid Fujian Provincial Electric Power Company Limited, Fuzhou 350001; 2. Sate Grid Fujian Provincial Electric Power Company Limited, Electric Power Tecnology and Research Institute, Fuzhou 350001; 3. College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350108 |
|
|
Abstract Depolarization current analysis is a better method for reflecting characteristics of the polarization process of dielectric response. The inner relaxation characteristics of depolarization current are studied in this paper. Two new characteristic quantities including sub-lines and its energy are introduced so as to further analyze the relationship between sub-lines energy and aging condition of oil-paper insulation, and the correspondence between sub-lines and the compositions of oil-paper insulation. And then a method to distinguish aging condition of oil-paper insulation is derived. Results show that, the sensitivity of sub-lines energy is sensitive to aging condition, sub-lines energy increases with the lower insulation level .The state of insulating oil is closely related to sub-lines of small time constant. The state of insulating paper is closely related to sub-lines of big time constant. So, depolarization current sub-lines and its energy can be accepted as the criterion of insulation diagnosis. The research will be one of effective means in the assessment of oil-paper insulation aging status.
|
Published: 02 June 2015
|
|
|
|
Cite this article: |
Wu Wenxuan,Zhang Konglin,Cai Jinding等. Aging Condition Evaluation of Oil-Paper Insulation based on Depolarization Current Sub-lines[J]. Electrical Engineering, 2015, 16(06): 25-28.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2015/V16/I06/25
|
[1] 许渊, 刘有为, 王文焕, 等. 大型电力变压器油纸绝缘含水量的介质响应诊断技术[J]. 中国电机工程学报, 2012, 32(33): 133-140. [2] 王晓剑, 吴广宁, 李先浪, 等. 酸值对变压器油纸绝缘系统回复电压参数影响规律研究[J]. 电力自动化设备, 2013, 33(12): 133-139. [3] 唐勇波, 桂卫华, 彭涛, 等. 基于互信息变量选择的变压器油中溶解气体浓度预测[J]. 仪器仪表学报, 2013, 34(7): 1492-1498. [4] 田杰, 段绍辉, 许昊, 等. 温度及老化状态对油纸绝缘时域介电响应特性影响的实验研究[J]. 中国电机工程学报, 2012, 32(z1): 69-75. [5] 李军浩, 司文荣, 姚秀, 等. 油纸绝缘变压器老化状态评估的极化/去极化电流技术研究[J]. 仪器仪表学报, 2009, 30(12): 2605-2611. [6] 李陈, 雷勇, 周凯, 等. 极化去极化电流技术用于诊断XLPE电缆绝缘老化状态[J]. 电工电能新技术, 2014(4): 32-35, 66. [7] Jota P, Islam S M, Jota F G. Modeling the polarization spectrum in composite oil/paper insulation systems[J]. Dielectrics and Electrical Insulation, IEEE Transactions on, 1999, 6(2): 145-151. [8] Saha T K, Purkait P, Müller F. Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements[J]. IEEE Transactions on Power Delivery, 2005, 20(1): 149-157. [9] 金维芳. 电介质物理学[M]. 北京: 机械工业出版社, 1997. [10] 江修波, 张涛, 黄彦婕. 变压器油纸绝缘极化谱的仿真研究[J]. 电力自动化设备, 2011, 31(2): 31-35. [11] 肖中男. 油纸绝缘老化的极化去极化电流法仿真及试验研究[D]. 重庆: 重庆大学电气工程, 2011. [12] 唐盼, 尹毅, 吴建东, 等. 基于去极化电流法的变压器油纸绝缘状态[J]. 电工电能新技术, 2012, 31(4): 39-42, 47. [13] Saha T K, Purkait P. Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers[J]. Dielectrics and Electrical Insulation, IEEE Transactions on, 2004, 11(1): 144-154. |
|
|
|