Abstract An optimal measurement placement algorithm in the distribution network based on branch-observed is proposed in order to make the distribution network totally observable. Firstly, the observation of the distribution network is analyzed, and the basic optimal model of the measurement placement based on the branch-observed is established. Then an improved model is considered and the measurement placement is more practical. At last, the model has been solved and the correctness of the proposed algorithm has been verified in the 37-bus and 69-bus distribution network.
|
Published: 22 March 2016
|
|
|
|
Cite this article: |
Dai Guimu,Wang Mengmeng,Zhou Xin. The Study of Optimal Measurement Placement in the Distribution Network[J]. Electrical Engineering, 2016, 17(3): 6-9.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2016/V17/I3/6
|
[1] 卫志农, 孙国强, 常宝立, 等. 考虑电力系统潮流直接可解的同步相量量测单元最优配置[J]. 电网技术, 2005, 29(1): 65-68. [2] 罗毅, 赵冬梅. 电力系统PMU最优配置数字规划算法[J]. 电力系统自动化, 2006, 30(9): 20-24. [3] 刘新东, 江全元, 曹一家. N -1条件下不失去可观测性的PMU优化配置方法[J]. 中国电机工程学报, 2009, 29(10): 47-51. [4] 王家林, 夏立, 吴正国, 等. 电力系统PMU最优配置新方法[J]. 电力系统及其自动化学报, 2011, 23(6): 1-5. [5] 徐岩, 郅静. 基于改进自适应遗传算法的PMU优化配置[J]. 电力系统保护与控制, 2015, 43(2): 55-62. [6] 邢洁, 韩学山, 武鹏. 使潮流方程直接可解的PMU配置方法的改进[J]. 电网技术, 2006, 30(11): 30-34. [7] 李泽文, 易志鹏, 杨毅, 等. 基于遗传算法的电网故障行波定位装置的优化配置[J]. 电力系统保护与控制, 2015, 43(3): 77-83. [8] 邓丰, 陈楠, 曾祥君, 等. 基于图论的电网故障行波定位装置最优配置算法[J]. 电力系统自动化, 2010, 34(11): 87-92. [9] 陈得治, 郭志忠. 基于表计配置的配电网可观测性分析[J]. 中国电机工程学报, 2005, 25(12): 35-41. [10] 高亚静, 张占龙, 吴文传, 等. 配电网量测配置评估及优化[J]. 中国电力, 2014, 47(7): 39-44. [11] 徐飞. 配网自动化条件下的FTU优化配置[J]. 四川电力技术, 2013, 36(2): 48-53. |
|
|
|