Abstract This paper describes the currently widely used in Smart Substation clock synchro- nization and time synchronization of smart substation safe and stable operation of the significance, introduces a kind of based on the principle of SNTP ping-pong to achieve all automation equipment in the substation intelligent time synchronization scheme of online monitoring system. A monitoring method based on the synchronized pulse monitoring device is proposed to realize the monitoring scheme of the merging unit sampling synchronous pulse, which is used for real-time monitoring of the synchronous pulse, and the monitoring data and its own state are sent to the substation station control network through MMS, and its reliability is verified by the test platform. This scheme has some reference value for improving the reliability of the intelligent substation using SV data networking mode.
|
Published: 19 May 2016
|
|
|
|
[1] 翁军美. 电网自动化系统时钟设备同步实时监测系统研究与应用[D]. 杭州: 浙江大学, 2010. [2] 于跃海, 张道农, 胡永辉, 等. 电力系统时间同步方案[J]. 电力系统自动化, 2008, 32(7): 82-86. [3] 国家电网公司. 关于开展厂站时钟同步装置应用情况调研的通知[Z]. 北京, 2013. [4] 吕航, 李力. 变电站同步信号异常对保护装置影响及对策[J]. 电力系统自动化, 2012, 36(19): 89-93. [5] 国家能源局. DL/T 282—2012. 合并单元技术条件[S]. 北京: 中国电力出版社, 2012. [6] 胡锦麟, 施松江. 晶体振荡器的对数老化规律[J]. 电子技术, 1980, 12(12): 17-19. |
|
|
|