The Automatic Calibration Method and Design for Virtual Terminal Connection based on “Six Unification” Specifications |
Shi Hui1, Ji Hui2, Li Yan2, Li Peng3, Liu Zhanpeng3 |
1. Yangzhou Power Supply Company, Jiangsu, Yangzhou, Jiangsu 225001; 2. Jiangsu Electric Power Company, Nanjing 211000; 3. Nanjing Five-C Smart Power Grid Technology Co., Ltd, Nanjing 210024 |
|
|
Abstract In present smart substation SCD configuration lack of virtual terminal check by offline, and need the field staff check the virtual terminal by a lot of online tests. Based on “six unification” specifications, this article establish a virtual terminal connection standard template library, propose a batch of automatic calibration method. This method can check virtual terminal with the virtual terminal connection standard template library one by one, then show the results to customer.
|
Published: 22 June 2016
|
|
|
|
Cite this article: |
Shi Hui,Ji Hui,Li Yan等. The Automatic Calibration Method and Design for Virtual Terminal Connection based on “Six Unification” Specifications[J]. Electrical Engineering, 2016, 17(6): 120-123.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2016/V17/I6/120
|
[1] 国家电网公司发布. DW 1161—2013. 线路保护及辅助装置标准化设计规范[S]. 2014. [2] 国家电网公司发布. DW 1396—2012. IEC 61850工程继电保护应用模型[S]. 2014. [3] 陈盼, 林传伟, 汤惠芳, 等. 基于关键字符匹配的虚端子自动关联方法[J]. 电力系统保护与控制, 2013, 41(18): 132-137. [4] 宋杰, 高亮, 鲍伟, 等. 基于协同测试系统的智能变电站GOOSE虚端子关联检测研究[J]. 电力系统保护与控制, 2012, 40(24): 138-142. [5] 高亚栋, 朱炳铨, 李慧, 等. 数字化变电站的“虚端子”设计方法应用研究[J]. 电力系统保护与控制, 2011, 39(5): 124-127. |
|
|
|