Research on New Method of Electric Maintenance for 110~220kV Multi-Circuit Strain-Resistant Transmission Lines on the Same Tower |
Long Chenhai, Zou Dehua, Yi Ziqi, Li Wen, Li Jinliang |
Hunan Provincial Live Working Center of State Grid, Changsha 410007 |
|
|
Abstract In order to ensure the power supply reliability of multi-circuit transmission lines on the same tower. Live operation of multi-circuit transmission lines on the same tower has become a research hotpot. Arming at the current technical difficulties of electric maintenance for 110~220kV multi-circuit strain-resistant transmission lines on the same tower, The structural mechanics analysis and accessory apparatus have been carried out to support the reverse operation method for replacing strain insulator. Difficulties such as small working space, low margin of safety on electric maintenance for 110~220kV multi-circuit strain-resistant transmission lines on the same tower can be solved by the method.
|
Published: 24 August 2016
|
|
|
|
Cite this article: |
Long Chenhai,Zou Dehua,Yi Ziqi等. Research on New Method of Electric Maintenance for 110~220kV Multi-Circuit Strain-Resistant Transmission Lines on the Same Tower[J]. Electrical Engineering, 2016, 17(8): 77-81.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2016/V17/I8/77
|
[1] 胡毅, 刘凯. 带电作业技术研究与标准制定[J]. 高电压技术, 2012.11, 38(11). [2] 雷冬云. 带电作业人员资质认证培训专用教材-配电线路[M]. 北京: 中国电力出版社, 2012. [3] 孙建龙, 吴锁平. 同塔多回架空输电线路设计[J]. 江苏电机工程, 2005, 24(2): 1-3. [4] 胡丹晖, 蔡汉生, 涂彩琪, 等. 同杆并架双回线路电气特性研究[J]. 高电压技术, 2005, 31(4): 21-23. [5] 刘洪正, 刘凯, 孟海磊, 等. ±660kV直流同塔双回输电线路带电作业试验研究[J]. 高电压技术, 2011, 37(12): 2997-3005. [6] 胡毅, 王力农, 刘凯, 等. 750kV输电线路带电作业安全防护研究[J]. 高电压技术, 2006, 32(10): 1-4. [7] 胡毅. 送变电带电作业技术[M]. 北京: 中国电力出版社, 2004. [8] 马志坚, 傅春蘅. 500kV同塔多回输电线路技术及其推广应用[J]. 电力设备, 2005(10): 25-27. [9] 窦飞, 李树森. 500kV同塔四回架空送电线路电场分布的研究[J]. 江苏电机工程, 2004(1): 11-16. [10] 余朝胜. 220kV及110kV六回路同塔线路的设计应用[J]. 电力建设, 2008, 29(8): 50-54. |
|
|
|