Sonic-electrical combined orientation study on an abnormal PD signal in a substaiton |
Zheng Rongsheng |
Meizhou Power Supply Bureau of Guangdong Power Grid Co., Ltd, Meizhou, Guangdong 514000 |
|
|
Abstract Since high level TEV signal have been detected in various locations in a 35kV substation, we carried out PD detection, recognition and orientation experiment in the substation. First, according the UHF, ultrasonic and high frequency current probes' measurement, we judged that it's floating discharge. Then, according the orientation process, we found the location of the PD source.
|
Received: 18 September 2017
Published: 18 April 2018
|
|
|
|
Cite this article: |
Zheng Rongsheng. Sonic-electrical combined orientation study on an abnormal PD signal in a substaiton[J]. Electrical Engineering, 2018, 19(4): 100-103.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2018/V19/I4/100
|
[1] 郭俊, 吴广宁, 张血琴, 等. 局部放电检测技术的现状和发展[J]. 电工技术学报, 2005, 20(2): 29-35. [2] 郑书生. 变压器绕组中局部放电特高频定位方法研究[D]. 北京: 华北电力大学, 2015. [3] 谢庆. 基于空间谱估计的变压器局放超声阵列定位方法研究[D]. 北京: 华北电力大学, 2010. [4] 唐志国, 李成榕, 黄兴泉, 等. 基于辐射电磁波检测的电力变压器局部放电定位研究[J]. 中国电机工程学报, 2006, 26(3): 96-101. [5] 罗勇芬, 李彦明, 刘丽春. 基于超高频和超声波相控接收原理的油中局部放电定位法仿真研究[J]. 电工技术学报, 2004, 19(1): 35-39. [6] 王国利, 郝艳捧, 李彦明. 电力变压器局部放电定位方法的现状和前景[J]. 变压器, 2001, 38(11): 22-27. [7] 陈娇. 基于能量相关搜取时间差算法的变压器局部放电定位研究[D]. 重庆: 重庆大学, 2009. [8] 侯慧娟, 盛戈皞, 孙岳, 等. 基于电磁波信号传播衰减模型的变电站局部放电定位方法[J]. 电工技术学报, 2014, 29(6): 326-332. [9] 麦茜坚, 钟悦, 唐明, 等. 基于TEV传感器与TOA算法的高压开关柜局部放电定位方法的研究[J]. 电气技术, 2015, 16(6): 1-6. [10] 律方成, 金虎, 王子建, 等. 基于组合核多特征融合的GIS局部放电检测与识别[J]. 电工技术学报, 2014, 29(10): 334-340. [11] 张凯, 孙亚明, 胡春江, 等. GIS设备局部放电检测技术研究[J]. 电气技术, 2014, 15(9): 66-69. [12] 唐炬, 朱伟, 孙才新, 等. GIS局部放电的超高频检测[J]. 高电压技术, 2003, 29(12): 22-23, 55. [13] 王晓蓉, 杨敏中, 严璋. 电力设备局部放电测量中抗干扰研究的现状和展望[J]. 变压器, 2002, 39(S1): 31-35. |
|
|
|