Optimization design of 220kV indoor substation based on merged distribution room |
Qiang Dingjian, Li Haifeng, Xiong Jing, Chen Bin |
China Energy Engineering Group Jiangsu Power Design Institute Co., Ltd, Nanjing 210000 |
|
|
Abstract Concerned of the large occupied area and building area of 220kV substation, the paper is focused on optimization design of 220kV indoor substation. Merged distribution room is applied, in which switchgear of different voltage levels and secondary panels are modular designed and arranged. Room clear height is declined by the fixed-up lifting method and horizontal arrangement of testing bushing. Compared with standard design, the optimization scheme has the advantages of saving 81.4% building area and 38.3% occupied area.
|
Received: 11 October 2017
Published: 18 April 2018
|
|
|
|
Cite this article: |
Qiang Dingjian,Li Haifeng,Xiong Jing等. Optimization design of 220kV indoor substation based on merged distribution room[J]. Electrical Engineering, 2018, 19(4): 77-82.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2018/V19/I4/77
|
[1] 秦建新. 城市变电站的发展趋势及其特点[J]. 天津电力技术, 2002(2): 10-12. [2] 于国梅, 史卓鹏, 罗炜. 基于国家电网通用设计方案的220kV户内变电站总平面布置的优化[J]. 山西电力, 2017(1): 15-18. [3] 刘丽, 张楠, 张嵩, 等. 智能变电站预制式二次设备布置及优化建议[J]. 电气技术, 2017, 18(6): 111-115. [4] 刘然. 变电站平面布置设计的一些优化[J]. 电气技术, 2016, 17(4): 142-145. [5] 况骄庭. 500kV智能变电站220kVHGIS配电装置设计优化[J]. 电力建设, 2012(8): 40-43. [6] 王小波. 新一代110kV智能变电站总平面及各级配电装置布置优化设计[J]. 湖北电力, 2013(12): 1-5. [7] 胡頔, 卓杰彬, 王青云, 等. 隔离式断路器在新一代智能变电站中的应用[J]. 电气开关, 2016, 54(1): 83-85. [8] 邱新刚, 郑跃, 孔宪扬. 220kV变电站风帆式联合出线构架受力计算分析[J]. 安徽建筑, 2015, 22(6): 132-133. [9] 钱南淳, 钱江, 高睿. 标准装配式智能变电站建设中“两型一化”的应用及成效[J]. 华东电力, 2014, 42(7): 1424-1427. [10] 肖向东, 司为国, 戴阳, 等. 预制装配式变电站设计和建造技术研究[J]. 建筑技术, 2008, 39(12): 939-942. [11] 中国南方电网公司输变电工程标准设计[M]国南方电网公司输变电工程标准设计[M]. 北京:中国电力出版社, 2013. [12] 西北电力设计院. 高压配电装置设计技术规程DL/T5352—2006[S]. [13] 刘振亚. 国家电网公司输变电工程通用设计110(66)、 -750kV智能变电站部分[M]. 北京: 中国电力出版社, 2011. |
|
|
|