The scheme of power quality data interchange format |
Cheng Li, Li Shaoqing, Li Dewen, Zhu Herong, Xiong Muwen |
NR Electric Co., Ltd, Nanjing 211102 |
|
|
Abstract With the development of economy in China, the demand for power quality of grid is getting higher. It is very important to correctly monitor the power quality data. Based on IEC 61000-4-30 standard, this paper proposes a scheme of PQDIF. The scheme takes the 10 cycle data as the statistical basis, strictly comply with the IEC 61000-4-30 A-level standard, and realizes the file format of PQDIF correctly and completely. On the basis of this scheme, a power quality monitoring terminal is developed in accordance with the standard system. HTM bus as the transmission channel between CPU and DSP is used and statistical data to the operating system is transmitted. The operating system uses MySQL database as storage engine, and provides service interfaces for applications such as IEC 61850, LCD and so on. It realizes the storage, query and deletion of PQDIF.The test platform is built, and the test results show that the scheme meets the requirements of IEC 61000-4-30 standard. Research and development of power quality monitoring terminal has been successfully applied in Anhui, Sichuan and Chongqing and other places, the operation is stable and reliable, and provides a solid data base for the power quality control of users.
|
Received: 31 January 2018
Published: 23 October 2018
|
|
|
|
[1] 彭卉, 邹舒, 付永生, 等. 冲击负荷接入电网的电能质量分析与治理方案研究[J]. 电力系统保护与控制, 2014, 42(1): 54-61. [2] 吕志盛, 闫立伟, 罗艾青, 等. 新能源发电并网对电网电能质量的影响研究[J]. 华东电力, 2012, 40(2): 251-255. [3] 聂晶晶. 电能质量监测系统及PQDIF数据存储格式的研究[D]. 南京: 东南大学, 2006. [4] IEC 61000-4-30 Edition 2.0[S]. 2008-10. [5] IEEE Recommended Practice for the Transfer of Power Quality Data[S]. Published by The Institute of Electrical and Electronics Engineers, Inc. 3 Park Avenue, New York, USA, 2004. [6] 朱伟立, 王俊, 王巍, 等. PQDIF在嵌入式电能质量监测终端上的实现与应用[J]. 江苏电机工程学报, 2011, 30(2): 59-62. [7] 杜景琦. 基于ARM-Linux嵌入式电能质量监测仪的研究与设计[D]. 长春: 东北电力大学, 2008. [8] 朱何荣, 程立, 熊慕文. 闪变测量时域算法改进与实现方法[J]. 电气技术, 2016, 17(11): 72-77. [9] 余晓鹏, 李琼林, 杜习周, 等. 基于IEC 61850的电能质量监测终端数据分析及模型实现[J]. 电力系统自动化, 2011, 35(4): 56-60. [10] 熊慕文, 朱何荣. 电能质量监测终端IEC 61850建模方案设计[J]. 电气技术, 2014, 15(12): 85-88. [11] 王平, 高阳, 王林泓, 等. 基于DSP与FPGA的实时电能质量监测终端系统[J]. 电力系统保护与控制, 2012, 40(12): 125-129. [12] 吴垠, 余瑾, 郭磊. MySQL数据库在嵌入式Linux平台上的移植和应用[J]. 电子技术研发, 2011. |
|
|
|