Research and development of high-precision distribution network single-phase ground fault detection and location system |
Liu Hongwen1, Guo Hui2, Wang Ke1, Xu Yu2, Yu Qinxue2 |
1. Electric Power Research Institute of Yunnan Power Grid Co., Ltd, Kunming 650217; 2. Department of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049 |
|
|
Abstract In order to solve the difficulties in location of small current grounding faults in distribution network, a new single-phase ground fault detection and location system for distribution network lines is designed and developed. The principle of fault detection and location of the system is to obtain the zero-mode voltage through the Karenbuaer phase-mode transformation and use the zero-mode voltage to judge whether the fault has occurred, and use the B-type traveling wave method to measure the fault. The system first uses the capacitor divider to extract the fault transient voltage signal. After simple analysis and processing of the data by the DSP, the fault information is summarized into the upper computer through the IoT communication module, and the upper computer analyzes and compares the data uploaded by each detecting device. The fault line selection is realized, and the nanosecond timing module is used to synchronously time the system, which can improve the measurement accuracy of the line wave arrival time of the line monitoring device to the nanosecond level, thereby improving the accuracy of the traveling wave distance measurement.
|
Received: 28 August 2019
Published: 18 January 2020
|
|
|
|
Cite this article: |
Liu Hongwen,Guo Hui,Wang Ke等. Research and development of high-precision distribution network single-phase ground fault detection and location system[J]. Electrical Engineering, 2020, 21(1): 60-66.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2020/V21/I1/60
|
[1] 刘文轩. 城市配电线路单相接地故障定位方法的研究[D]. 保定: 华北电力大学, 2012. [2] 张君琦, 杨帆, 郭谋发. 配电网高阻接地故障时频特征SVM分类识别方法[J]. 电气技术, 2018, 19(3): 37-43. [3] 唐金锐, 尹项根, 张哲, 等. 配电网故障自动定位技术研究综述[J]. 电力自动化设备, 2013, 33(5): 7-13. [4] 马腾. 10kV配电线路断线故障检测与定位研究[D]. 济南: 山东大学, 2013. [5] 牟之豫, 牟龙华, 朱吉然, 等. 小电流接地系统接地故障大数据分析平台数据库设计[J]. 电气技术, 2019, 20(6): 6-11, 29. [6] 施慎行, 董新洲, 周双喜. 单相接地故障行波分析[J]. 电力系统自动化, 2005(23): 29-32, 53. [7] 张飚, 和敬涵, 薄志谦. 基于凯伦贝尔变换的单端母线集成保护[J]. 继电器, 2006, 34(22): 1-4. [8] Pereira C, Zanetta L.An optimization approach for fault location in transmission lines using one terminal data[J]. Electric Power Energy System, 2007, 29(4): 290-296. [9] 张帅. 电容式高压取电方法及稳态特性研究[D]. 北京: 华北电力大学, 2015. [10] 肖磻飞. 智能配电网4G无线通信技术方案设计[J]. 通讯世界, 2017(1): 51-53. [11] 郑涛, 张翔, 杨耿杰, 等. 基于GPRS无线通信的配电网过电压录波装置的设计与实现[J]. 电气技术, 2016(1): 33-37. [12] 冯书玮. 基于IEEE1588技术的智能配电网时间同步系统研究[D]. 济南: 山东大学, 2014. [13] 毋金涛, 盛戈皞, 曾奕, 等. 输电线路在线监测装置供电电源的设计[J]. 电工技术, 2009(2): 33-35. [14] 皇甫羽飞. 电容式高压取电方法及雷电暂态研究[D]. 北京: 华北电力大学, 2015. |
|
|
|