Design of reduced-scale test line for DC electromagnetic environment at different altitudes |
Zhao Luxing1, Gao Lei2, Li Dapeng2, Bai Feng1 |
1. China Electric Power Research Institute, Beijing 100192; 2. Electric Power Research Institute of State Grid Tibet Electric Power Co., Ltd, Lhasa 850000 |
|
|
Abstract With the rapid development of China power grid, more and more UHV DC transmission lines will pass through high altitude areas. The lack of altitude correction method of DC electromagnetic environment has brought great difficulties to the design in high altitude DC project. In order to study the influence of altitude on the electromagnetic environment of DC transmission line, a DC reduced-scale test line which can be used in different altitude tests was designed in this paper. Through calculation and analysis, the conductor type of reduced-scale test line meeting the test requirements was determined, the value range of parameters such as length of test line, distance between poles and height of conductor to ground was given, and the voltage range during test was also defined. Four reduced-scaled test lines were constructed at an altitude of 50~4300m.Through the electromagnetic environment simulation tests at different altitudes, the electromagnetic environment distribution characteristics of DC transmission lines at different altitudes were preliminarily obtained, which laid a foundation for the further study on the altitude correction method of DC electromagnetic environment.
|
Received: 31 January 2020
|
|
|
|
Cite this article: |
Zhao Luxing,Gao Lei,Li Dapeng等. Design of reduced-scale test line for DC electromagnetic environment at different altitudes[J]. Electrical Engineering, 2020, 21(7): 24-29.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2020/V21/I7/24
|
[1] 舒印彪, 张文亮. 特高压输电若干关键技术研究[J]. 中国电机工程学报, 2007, 27(31): 1-6. [2] Liu Zehong, Zhang Fuxuan, Yu Jun, et al.Research on key technologies in ±1100kV ultra-high voltage DC transmission[J]. High Voltage, 2018, 3(4): 279-288. [3] 邓军, 肖遥, 楚金伟, 等. 云南-广东±800kV特高压直流输电线路可听噪声仿真计算与测试分析[J]. 高电压技术, 2012, 38(12): 3268-3276. [4] 张文亮, 于永清, 李光范, 等. 西藏高海拔试验基地的功能与设计[J]. 高电压技术, 2009, 35(8): 1785-1790. [5] 郭剑, 陆家榆, 张文亮. 特高压直流输电用电晕笼的设计(英文)[J]. 高电压技术, 2013, 39(8): 2022-2026. [6] 谢莉, 赵录兴, 陆家榆, 等. 有限长高压直流输电线路无线电干扰电磁场的计算方法研究[J]. 电工技术学报, 2016, 31(1): 96-102. [7] 尹晗, 郭剑, 张波, 等. 直流电晕笼中离子流场的计算[J]. 高电压技术, 2011, 37(3): 758-764. [8] 杨勇, 陆家榆, 鞠勇. 基于Deutsch假设法和有限元法的高压直流线路地面合成电场对比分析[J]. 电网技术, 2013, 37(2): 526-532. [9] 谢莉, 陆家榆, 赵录兴, 等. 特高压直流长、短输电线路可听噪声的转换关系研究[J]. 电网技术, 2013, 37(6): 1526-1530. [10] EPRI. HVDC Handbook[M]. USA, 1993: 274-277. [11] CISPR/TR 18-1. Radio interference characteri- stics of overhead power lines and high-voltage equipment, part 1: description of phenomena[S]. |
|
|
|