Abstract According to the requirements of the new generation intelligent substation secondary system for the hardware reliability of local equipment, this paper studies the method of hardware self-checking. In view of the difficulties in memory testing, a new detection method is proposed to improve the memory error correction ability and obtain the running status of hardware equipment in time. The newly designed local module has the function of abnormal active early warning and automatically identifies hidden faults of secondary equipment. Through the expansion of communication protocol, the hardware self-checking information is sent to the hardware self-checking monitoring system to realize the overall perception of the secondary equipment status of substation, which provides technical support for condition maintenance and improves the running reliability of equipment.
|
Received: 14 December 2019
|
|
|
|
Cite this article: |
Zhu Changyin,Liu Dongchao,Xia Yongjun等. Design of hardware self-diagnosis system based on local module[J]. Electrical Engineering, 2020, 21(7): 35-41.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2020/V21/I7/35
|
[1] 杨奇逊, 刘建飞, 张涛, 等. 现代微机保护技术的发展与分析[J]. 电力设备, 2003(5): 10-14. [2] 张桂青, 王建华, 张杭. 微机保护装置的自检技术[J]. 江苏电器, 2001(1): 15-17, 6. [3] 周文越, 李霞. 一起合并单元故障引起的保护误动事故分析[J]. 电测与仪表, 2018, 55(24): 22-26. [4] 陈强林, 张锋, 刘晓航, 等. 一起非电量保护装置误动原因分析与改进[J]. 电工电气, 2017(4): 40-42. [5] Wallmark J, Marcus S.Minimum size and maximum packing density of nonredundant semiconductor devices[J]. Proceedings of the IRE, 1962, 50(3): 286-298. [6] 王大方, 于知杉, 金毅, 等. 无位置传感器无刷直流电机无硬件滤波转子位置检测方法[J]. 电工技术学报, 2017, 32(19): 71-80. [7] 刘素贞, 李丽滨, 蔡智超, 等. 电磁超声检测系统中消除电磁干扰电路的设计[J]. 电工技术学报, 2016, 31(1): 80-84. [8] 洪博, 王莉, 毛健美, 等. 一种航天器一次母线故障在线检测定位方法[J]. 电工技术学报, 2016, 31(5): 118-125. [9] 邓勇, 黄烽, 陆榛, 等. 一起继电保护装置数据异常故障分析与对策[J]. 电气技术, 2017, 18(11): 138-141. [10] 邵贺锋, 全惠敏. 基于DSP的单相有源电力滤波器的研究与设计[J]. 电气技术, 2016, 17(11): 53-55, 67. [11] 黄丽晶. 基于PLC的电梯控制系统设计分析[J]. 电气技术, 2016, 17(11): 125-132. [12] Michalak S E, Harris K W, Hengartner N W, et al.Predicting the number of fatal soft errors in Los Alamos national laboratory's ASC Q supercomputer[J]. IEEE Transactions on Device and Materials Reliability, 2005, 5(3): 329-335. [13] Hazucha P, Svensson C.Impact of CMOS technology scaling on the atmospheric neutron soft error rate[J]. IEEE Transactions on Nuclear Science, 2000, 47(6): 2586-2594. [14] ADSP-BF54x Blackfin® Processor Hardware Refer- ence[Z].DSP-BF54x Blackfin® Processor Hardware Refer- ence[Z]. ADI, 2013. [15] 赵天恩, 周强, 孙浩, 等. 基于BF548的内存软错误监视和自纠错设计[J]. 工业控制计算机, 2019, 31(10): 77-79. |
|
|
|