Research on optimization of voltage equalization system for 252kV high speed circuit breakers |
WANG Zhiyong, HAN Yuhui, CHEN Xin |
NR Electric Power Electronics Co., Ltd, Changzhou, Jiangsu 213025 |
|
|
Abstract In the structural design of high voltage equipment, the electric field distribution is an important factor that cannot be ignored. Therefore, the electric field distribution should be analyzed and verified in the research and development stage of fault current breaker. In this paper, the 252kV fault current breaker structure is used as the prototype to establish a three-dimensional simplified model for electric field simulation. The influence of the structure, size and installation distance of the voltage equalizing device on the electric field distribution is simulated and analyzed. Through comparative research, the structure, installation position and size of the voltage equalizing device are optimized and configured. Finally, a tubular type voltage equalizing device with a pipe diameter of 40mm and an installation distance of 20mm is selected. This plan can control the overall maximum electric field intensity below 2.3kV/mm, and the analysis results can provide reference for product optimization.
|
Received: 07 August 2023
|
|
|
|
Cite this article: |
WANG Zhiyong,HAN Yuhui,CHEN Xin. Research on optimization of voltage equalization system for 252kV high speed circuit breakers[J]. Electrical Engineering, 2023, 24(9): 55-59.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2023/V24/I9/55
|
[1] 余爽, 赵科. 一起1100kV气体绝缘金属封闭开关设备母线放电故障分析[J]. 电气技术, 2021, 22(4): 94-97. [2] 袁娟, 刘文颖, 董明齐, 等. 西北电网短路电流的限制措施[J]. 电网技术, 2007, 31(10): 42-45. [3] 刘鹏, 郭伊宇, 吴泽华, 等. 特高压换流站大尺寸典型电极起晕特性的仿真与试验[J]. 电工技术学报, 2022, 37(13): 3431-3440. [4] 赵强, 曹力雄. 一起特高压换流站500kV断路器击穿故障分析与处理[J]. 电气技术, 2021, 22(8): 58-61, 68. [5] 方书博, 李牧, 项涛, 等. 750kV变电站导线场强及电晕噪声分布[J]. 水电能源科学, 2015, 33(4): 170-173. [6] 张占龙, 王科, 唐炬, 等. 变压器电晕放电紫外脉冲检测法[J]. 电力系统自动化, 2010, 34(2): 84-88. [7] 孙海涛, 杨杰, 张迈, 等. 750 kV变电站噪声衰减与降噪措施[J]. 电气应用, 2019, 38(9): 27-33. [8] 李学宝, 吴昊天, 程璐莹, 等. 直流电晕放电无线电干扰随机时域计算模型研究[J]. 电工技术学报, 2023, 38(6): 1531-1540, 1583. [9] 张跃, 苏淮北, 何明鹏, 等. 双极性方波场下电晕老化对环氧树脂空间电荷特性的影响[J]. 高电压技术, 2022, 48(12): 4731-4738. [10] 毕茂强, 董扬, 陈曦, 等. 表面状态对硅橡胶电晕老化进程及特性的影响研究[J]. 中国材料进展, 2022, 41(6): 429-434. [11] 毛艳, 丁玉剑, 郭贤珊, 等. ±1100 kV PLC电抗器均压屏蔽装置的结构优化[J]. 高电压技术, 2021, 47(4): 1436-1442. [12] 刘鹏, 吴泽华, 程建伟, 等. 特高压多端柔直换流站直流场均压屏蔽金具电场分布仿真分析与差异化优化方法[J]. 电网技术, 2021, 45(6): 2405-2412. [13] 张翔, 孙健, 张子敬, 等. ±1100 kV换流阀屏蔽罩结构改进及U50试验[J]. 高电压技术, 2019, 45(11): 3693-3699. [14] 姚宏洋, 文卫兵, 谢晔源, 等. ±800 kV柔性直流换流阀阀塔均压优化设计[J]. 电力工程技术, 2021, 40(2): 178-184. [15] 高压开关设备和控制设备标准的共用技术要求: DL/T 593—2016[S] DL/T 593—2016[S]. 北京: 中国电力出版社, 2016. [16] 变电站控制电晕噪声技术导则 (导体金具类): Q/GDW 551—2010[S] Q/GDW 551—2010[S]. 北京: 中国电力出版社, 2011. [17] 输电线路降低可听噪声设计和建设导则: Q/GDW 550—2010[S] Q/GDW 550—2010[S]. 北京: 中国电力出版社, 2011. |
|
|
|