Analysis and Research of Grounding Modes of 750kV Transmission Line |
Li Yanjun1,Meng Lingzeng1,Wang Dongyu1,Liu Qing2 |
1. Tongchuan power supply company, Tongchuan, Shaanxi 727031; 2. Xi’an University of Science & Technology, Xi’an 710054 |
|
|
Abstract The ground wire of high voltage overhead line commonly composes a common overhead ground wire and an OPGW. The induced voltage and current of four grounding modes of a typical 750kV transmission line are calculated by ATP. It is shown that the induced current is largest when ground wire is grounded at each tower. When segment-insulated grounding at one tower is adopted, the longer the segment length is, the larger the induced voltage is. The results provide a basis for selection and improvement of OPGW grounding mode.
|
Published: 19 May 2015
|
|
|
|
Cite this article: |
Li Yanjun,Meng Lingzeng,Wang Dongyu等. Analysis and Research of Grounding Modes of 750kV Transmission Line[J]. Electrical Engineering, 2015, 16(05): 82-84.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2015/V16/I05/82
|
[1] 张雅婷, 高博, 施围. 750kV输电线路架空地线损耗的影响因素及降低方法研究[J]. 电磁避雷器, 2008, 221. [2] 王倩, 吴田, 施荣, 等. 750kV输电线路光纤复合架空地线的接线方式[J]. 高电压技术, 2011(37), 12. [3] 胡毅, 刘凯. 输电线路OPGW接地方式的分析研究[J]. 高电压技术, 2008, 34. [4] 黄旭峰. 光纤复合架空地线接线方式的改进[J]. 高电压技术, 2010(36), 2. [5] 傅宾兰. 光纤复合架空地线OPGW运行状况和防雷[J]. 中国电力, 2005, 38. [6] 张晓东, 张栋. 高压架空输电线路地线热稳定的计算[J]. 高电压技术, 2005(31), 5. [7] 曾林平, 张鹏, 冯玉昌, 等. 750kV线路架空地线感应电压和感应电流仿真计算[J]. 电网与清洁能源, 2008(24), 6. [8] 吴康平. 500kV线路绝缘地线的设计[J]. 电力建设, 2001(22), 11. |
|
|
|