Investigation and Cause Analysis of a Thunder Damage on the Automatic Meteorological Station |
Li Hongmei1, Jing Dongping2, Li Yufei3, Wang Yihao1 |
1. Changzhi Weather Bureau, Changzhi, Shanxi 046000; 2. Linfen Weather Bureau, Linfen, Shanxi 041000; 3. Wuxiang Weather Bureau, Wuxiang, Shanxi 046300 |
|
|
Abstract In this paper, a thunder and lightning accident occurred on an automatic meteorological station is analyzed and discussed in depth based on the modern lightning protection technology theory. The defects of the existing lightning protection device and the rectification opinions are put forward.
|
Received: 18 August 2015
Published: 18 August 2015
|
|
|
|
Cite this article: |
Li Hongmei,Jing Dongping,Li Yufei等. Investigation and Cause Analysis of a Thunder Damage on the Automatic Meteorological Station[J]. Electrical Engineering, 2015, 16(8): 113-115.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2015/V16/I8/113
|
[1] 桑二, 高栋斌, 樊家庆, 等. 半坡村“5.12”重大雷击伤亡事故调查分析[C]. 第八届中国国际防雷论坛, 2010: 330-331. [2] 侯俊玲, 李春华, 李文忠, 等. 自动站雷击故障分析检修一例[J]. 山西气象, 2012(3): 38-40. [3] 胡定, 陆晓丽. 一次雷击事故的调查分析与启示[J].气象研究与应用, 2011, 32(3): 108-110. [4] 中华人民共和国住房与城乡建设部. 建筑物防雷设计规范(GB 50057—2010)[Z]. 2010-11-03. [5] 中华人民共和国住房与城乡建设部. 建筑物电子信息系统防雷技术规范(GB 50343—2012)[Z]. 2012-12-28. |
|
|
|