The Application of EDSA in the Asynchronous Motor Start Calculation of Oil Filed |
Li Baoyun1,Tian Chuan2,Zhou Jiali1,Li Xiangguang1 |
1. China Petroleum Engineering Co., Ltd, Huabei Company, Renqiu, Hebei 062552; 2. Petrochina North China Petrochemical Company, Renqiu, Hebei 062552 |
|
|
Abstract Base on the study of large asynchronous motor start, this paper mainly talks about the different voltage drop caused by different start-up mode of MV motor to the motor itself, adjacent equipment, and different voltage grade busbar. Through the EDSA simulation of three start-up ways such as direct start-up, soft start-up and VFD start-up, analyzing the results, it draw conclusion that the importance of the soft start-up mode.
|
Published: 28 September 2015
|
|
|
|
Cite this article: |
Li Baoyun,Tian Chuan,Zhou Jiali等. The Application of EDSA in the Asynchronous Motor Start Calculation of Oil Filed[J]. Electrical Engineering, 2015, 16(9): 71-74.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2015/V16/I9/71
|
[1] 中国航空工业规划设计设计院. 工业与民用配电设计手册[M]. 3版. 北京: 中国电力出版社, 2005. [2] 田晨, 宋振洋, 詹雨桥, 等. 超大型电动机起动方法之比较[J]. 价值工程, 2014, 33(25): 78-79. [3] 姚剑. 软起动技术在电机控制中的应用[J]. 电气开关, 2002, 40(2): 16-18, 20. [4] 靳希, 沙旦华, 张立峰, 等. 大容量电动机起动对孤立小电网的影响[J]. 上海电力学院学报, 2011, 27(6): 579-582. [5] 刘宏伟. 大功率电机起动问题初探[J]. 机械工程与自动化, 2011(4): 158-159. [6] 梁佰兴. 浅论电机起动方式的选择[J]. 广东建材, 2010, 26(5): 175-176. [7] 田晨, 宋振洋, 詹雨桥, 等. 超大型电动机起动方法之比较[J]. 价值工程, 2014, 33(25): 78-79. |
|
|
|