Exploration and Application on Recover of Low Main Steam Temperature in Circulating Fluidized Bed Boiler |
Li Zifan |
Pingdingshan Coal, China Shenma Group Information and Communication Technology Development Company, Pingdingshan, He’nan 467021 |
|
|
Abstract The article analyzes in detail the reason of low main steam temperature ina circulating fluidized bed boiler. We discussed the control scheme of the default, and the utilization effect after reforming the system. By the introduction, a reference can be provided for judgement and analysis of anomalies in the operation of fluidized bed boilers.
|
Published: 20 April 2016
|
|
|
|
Cite this article: |
Li Zifan. Exploration and Application on Recover of Low Main Steam Temperature in Circulating Fluidized Bed Boiler[J]. Electrical Engineering, 2016, 17(4): 149-151.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2016/V17/I4/149
|
[1] 黄焕椿. 发电厂热力设备[M]. 北京: 水利电力出版社, 1985. [2] 任永红. 循环流化床锅炉使用培训教材[M]. 北京:中国电力出版社, 2007. [3] 邵和春. 汽轮机运行[M]. 2版. 北京: 中国电力出版社, 2006. [4] 李怀新, 王兴和, 尹民权, 等. 浅谈气脉冲吹灰器在锅炉预热器/省煤器上的应用[C]//全国电力行业循环流化床机组技术交流服务协作网年会, 2008: 864-865. |
|
|
|