On Line Fault Location of Distribution Network |
Zhang Li, Li Ping |
Beijing Information Science & Technology University, Beijing 100192 |
|
|
Abstract When the single-phase-to-ground fault occurs in neutral point resonant grounded system resonant, the fault current is small and the fault location is very difficult. In this paper, the principle of single-phase-to-ground fault occurred in neutral point resonant system is analyzed, and the variation characteristics of zero sequence current on each line are given with the adjustment of arc suppression coil. The fault information matrix is present based on the increment of the zero sequence current, and section fault location is realized by the matrix operation of fault information matrix with network relevant matrix which combining the topological relationship between the section and the monitoring point. Simulation results show the effectiveness of the proposed method.
|
Published: 20 September 2017
|
|
|
|
[1] 潘贞存, 张慧芬, 张帆, 等. 信号注入式接地选线定位保护的分析与改进[J]. 电力系统自动化, 2007, 31(4): 71-75. [2] 张姝, 何正友, 林圣, 等. 基于充放电暂态特征的谐振接地系统单相接地故障定位方法[J]. 电力系统保护与控制, 2013, 41(9): 13-20. [3] 张惠娟, 郑文龙, 冯垚, 等. 基于行波法的谐振接地电网单相接地故障定位方法[J]. 电气应用, 2015, 34(15): 68-71. [4] 唐金锐, 尹项根, 张哲, 等. 零模检测波速度的迭代提取及其在配电网单相接地故障定位中的应用[J]. 电工技术学报, 2013, 28(4): 202-211. [5] 周永勇, 周湶, 杨柱石, 等. 采用CWP-EM和IPSO- WNN的配电网单相接地故障定位[J]. 高电压技术, 2010, 36(4): 873-877. [6] 郭谋发, 黄建业, 杨耿杰. 谐振接地系统故障区段模糊信息融合定位方法[J]. 电力系统保护与控制, 2012, 40(10): 65-70. [7] 马士聪, 徐丙垠, 高厚磊, 等. 检测暂态零模电流相关性的小电流接地故障定位方法[J]. 电力系统自动化, 2008, 32(7): 48-52. [8] 黄超艺, 蔡金锭, 李天友, 等. 分布式接入配网单相接地故障定位适应性分析[J]. 电气技术, 2015, 16(7): 58-62. [9] 童宁, 余梦琪, 林湘宁, 等. 基于相电流高频特征识别的配电网故障指示器原理[J]. 电工技术学报, 2015, 30(12): 465-471. [10] 孙九顺. 配电网小电流单相接地故障特性及定位技术研究[J]. 电气技术, 2015, 16(5): 66-69. [11] 倪广魁, 鲍海, 张利, 等. 基于零序电流突变量的配电网单相故障带电定位判据[J]. 中国电机工程学报, 2010, 30(31): 118-122. [12] 张利. 中性点非有效接地系统单相接地故障定位方法研究[D]. 北京: 华北电力大学, 2009. [13] 朱发国, 孙德胜, 姚玉斌, 等. 基于现场监控终端的线路故障定位优化矩阵算法[J]. 电力系统自动化, 2000, 24(15): 42-44. [14] 梅念, 石东源, 杨增力, 等. 一种实用的复杂配电网故障定位的矩阵算法[J]. 电力系统自动化, 2007, 31(10): 66-70. |
|
|
|