|
|
Research on Low Voltage Variable-frequency Drive Anti-electricity Shaking Scheme |
Jiang Wandong, Zhou Haitao, Wang Xiaokun, Zhang Zheng |
Jiangsu State Grid Automation Technology Co., Ltd, Kunshan, Jiangsu 215311 |
|
|
Abstract Low-voltage VFD is sensitive to voltage fluctuation. Because of voltage dips, unplanned stop of VFD happened frequently. This paper made deep research on DC-Bank scheme and restart scheme of VFD anti-electricity shaking, analyzed problems of common solutions, and proposed a relevant solution. The conclusion of this paper has a certain significance to the choice of anti-electricity shaking scheme of low-voltage VFD.
|
Published: 20 September 2017
|
|
|
|
Cite this article: |
Jiang Wandong,Zhou Haitao,Wang Xiaokun等. Research on Low Voltage Variable-frequency Drive Anti-electricity Shaking Scheme[J]. Electrical Engineering, 2017, 18(9): 81-84.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2017/V18/I9/81
|
[1] 刘玉杰, 周博, 张玉星. 变频器防晃电改造方案探讨[J]. 科技信息, 2013(17): 116-117. [2] 庞胜汉, 江伟. 防低压穿越装置在给煤变频器上的应用[J]. 电气技术, 2013, 14(12): 116-118. [3] ABB ACS800变频器说明书[Z]. [4] 姚新良, 黄学良. 火电机组一类辅机变频器低电压穿越改造技术方案研究[J]. 电气技术, 2015, 16(12): 26-30. [5] 唐颖倩. 给粉机变频器低电压穿越改造方案对比及实施[J]. 科技风, 2015(3): 89-90. [6] 盛小桥, 王傲林, 周林. 低电压穿越技术在1000MW机组给煤机变频器上应用[J]. 中国电业(技术版), 2015(2): 52-54. [7] 张祖平, 董永乐. 火电厂低压变频器低电压穿越的影响及理论分析[J]. 内蒙古科技与经济, 2015(1): 71-72. [8] 栗向鑫. 火电机组辅机低电压穿越问题研究[J]. 华北电力技术, 2014(10): 43-47. [9] 王野, 姜万东, 迟玉国. 防晃电智能控制模块设计与分析[J]. 电气技术, 2015, 16(9): 43-46, 94. [10] 王蛇良. 防晃电技术在化工生产中的应用[J]. 电工技术, 2006(11): 73, 89. |
|
|
|