1. State Grid Tulufan Electric Power Supply Company, Urumqi 830011; 2. Xinjiang Electric Power Dispatching and Communication Center, Urumqi 830011; 3. State Grid Electric Power Research Institute of Xinjiang Electric Power Company, Urumqi 830011 |
|
|
Abstract Hami Area of Xinjiang is the sending terminal of ±800kV UHVDC transmission system from the Tianshan Station to the Zhongzhou Station. The local grid system is a complex one and facing relatively higher risk of sub/super synchronous oscillation than elsewhere as wind power and photovoltaic power in combination with thermal power are bundled and transmitted from here. In view of the shortcomings of the existing sub/super synchronous oscillation detecting and alarming system in the new energy pooling area of Xinjiang power grid, the improved method and optimized scheme are proposed. Three safeguards and two platforms have been deployed aim to detect and alarm respectively. Aiming at the shortcomings of the existing stability control system, an oscillation positioning method and an improved cutting scheme are proposed, and three lines of defense for the stability control system are established. The improved detecting, alarming and control system can monitor oscillations in real time, alarm in time and suppress as quick as possible, ensuring stable operation of the power grid.
|
Received: 31 March 2018
Published: 31 August 2018
|
|
|
|
Cite this article: |
Chen Jun,Wang Chen,Nan Dongliang等. Research on sub/super-synchronous oscillation detecting, alarming and control technology used in the new energy pooling area[J]. Electrical Engineering, 2018, 19(8): 72-76.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2018/V19/I8/72
|
[1] 吴萍, 陈昊, 赵兵, 等. 风光火打捆交直流混联外送系统交互影响及稳定性研究[J]. 电网技术, 2016, 40(7): 1934-1942. [2] 陈国平, 李明节, 许涛, 等. 关于新能源发展的技术瓶颈研究[J]. 中国电机工程学报, 2017, 37(1): 20-27. [3] 张祎, 南东亮, 常喜强, 等. 适应智能调度的继电保护故障信息系统高级应用研发[J]. 电气技术, 2016, 17(5): 91-95. [4] 秦骏达, 毕天姝. 电力系统失去可观性情况下的故障定位方法[J]. 南方电网技术, 2017(9): 1-8. [5] 李文锋, 郭剑波, 李莹, 等. 基于WAMS的电力系统功率振荡分析与振荡源定位(1)割集能量法[J]. 中国电机工程学报, 2013(25): 41-46, 9. [6] 樊海峰. 电力系统PMU优化配置研究[D]. 杭州: 浙江大学, 2013. [7] 陈剑, 周宇植. 基于PMU的分布式次同步振荡在线辨识方法[J]. 电气技术, 2017, 18(10): 92-95. [8] 郭小龙, 李渝, 李珏, 等. PMU装置次同步振荡监测功能扩展的标准讨论[J]. 智能电网, 2016, 4(9): 924-928. [9] 王娜娜, 廖清芬, 唐飞, 等. 基于割集能量及灵敏度的强迫功率振荡扰动源识别[J]. 电力自动化设备, 2013(1): 75-80. |
|
|
|