Failure analysis of Crowbar rectifier diode for wind power system |
Chen Ming, Huang Min |
CRRC Zhuzhou Institute Co., Ltd, Zhuzhou, Hu’nan 412000 |
|
|
Abstract In view of the fact that the rectifier diode of Crowbar wind power device is in the long-term operation of the inverter's switching pulse rectifier, high -di/dt and short turn-on time, the reverse recovery condition is poor, the soft factor is small, and the snappy is serious. According to the reverse recovery mechanism of PIN diode, the cause analysis of the failure cases occurred, and the improvement measures are proposed to provide a guarantee for the reliable operation of the product.
|
Received: 13 October 2018
Published: 21 May 2019
|
|
|
|
[1] 年珩, 程鹏, 贺益康. 故障电网下双馈风电系统运行技术研究综述[J]. 中国电机工程学报, 2015, 35(16): 4184-4197. [2] 叶希, 鲁宗相, 乔颖, 等. 大规模风电机组连锁脱网事故机理初探[J]. 电力系统自动化, 2012, 36(8): 11-17. [3] 张阳, 黄科元, 黄守道. 一种双馈风力发电系统低电压穿越控制策略[J]. 电工技术学报, 2015, 30(Z2): 153-158. [4] 蔚芳, 刘其辉, 谢孟丽, 等. 适应多类型故障的双馈风电机组低电压穿越综合控制策略[J]. 电力系统自动化, 2013, 37(5): 23-28, 133. [5] Jon Vidal, Gonzalo Abad, Joseba Arza, et al.Single- phase DC Crowbar topologies for low voltage ride through fulfillment of high-power doubly fed induction generator-based wind turbines[J]. IEEE Trans. Energy Conver, 2013, 28(3): 768-781. [6] 徐明辉, 李泽滔, 陶金. 基于Crowbar保护的双馈风力发电机低电压穿越研究[J]. 电气技术, 2014, 15(6): 48-51. [7] 黄晶, 朱武. 基于DFIG风电场联合保护的低电压穿越研究[J]. 电气技术, 2015, 16(9): 34-37, 82. [8] 杨印博, 杨林, 等. 一种Crowbar装置和电机[P]. 中国: CN103986341A, 2014-8-13. [9] 谭国俊, 凌臧, 徐世周. 一种双馈风力发电系统低电压穿越用Crowbar装置[P]. 中国: CN102412599A, 2012-4-11. [10] 杨恩星. 一种新型的能量回馈型DFIG低电压穿越Crowbar拓扑[J]. 上海电气技术, 2012, 5(3): 14-17, 22. [11] Josef L.功率半导体器件原理、特性和可靠性[M]. 北京: 机械工业出版社, 2013. [12] 周悦. 二极管反向恢复电流瞬变的研究[D]. 沈阳: 沈阳工业大学, 2013. [13] 方春恩, 李威, 李先敏, 等. PIN型功率二极管动态特性物理模型参数提取[J]. 电工技术学报, 2015, 30(6): 208-215. [14] IXYS. MDD710-26N2说明手册[Z]. 2011. |
|
|
|