Electrical properties of the ITER BCC coil insulation flange |
Xin Jijun1, Dai Wenhua1,2, Du Shuangsong1, Wang Lin1, Wei Jing1 |
1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031; 2. University of Science and Technology of China, Hefei 230026 |
|
|
Abstract The electric properties of the ITER BCC correction coil insulation flange were investigated in this paper. First, a tooling for shearing fatigue test of insulation pin of the insulation flange was designed and manufactured. The insulation resistance of the insulation pin after the fatigue test was measured and the results show that the insulation pin demonstrate a superior insulation resistance even after 60000 cycles, which is better than that of the ITER design requirement. And no cracks were found on the surface of the insulation pin after fatigue test. In addition, a high voltage insulation test method for the ITER BCC coil has been successfully designed to perform the electrical insulation test of the insulation flange. The test results show that the electrical insulation of the insulation flange meets the requirements of ITER.
|
Received: 19 November 2019
|
|
|
|
Cite this article: |
Xin Jijun,Dai Wenhua,Du Shuangsong等. Electrical properties of the ITER BCC coil insulation flange[J]. Electrical Engineering, 2020, 21(5): 6-9.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2020/V21/I5/6
|
[1] Libeyre P, Cormany C, Dolgetta N, et al.Preparation of the manufacture of the ITER correction coils[J]. Fusion Engineering and Design, 2013, 88(9/10): 1478-1481. [2] Fang C, Zhang S, Zhou Z, et al.Study on laser welding of case closure weld for ITER correction coil[J]. IEEE Transactions on Applied Superconductivity, 2014, 24(3): 4201103. [3] Fang Chao, Song Yuntao, Wei Jing, et al. Micro- structural characteristics of the laser welded joint of ITER correction coil sub case[J]. Fusion Engineering and Design, 2015, 98-99(B): 1960-1963. [4] Wei J, Wu W, Han S, et al.Progress of the ITER correction coils in china[J]. IEEE Trans. Appl. Supercond., 2014, 24: 4202005. [5] Xin Jijun, Fang Chao, Song Yuntao, et al.Micro- structure and mechanical properties of ITER correction coil case material[J]. IEEE Transactions on Applied Superconductivity, 2017, 27(6): 4201707. [6] 朱春阳, 戚岭娜, 童鑫. 配电变压器绝缘状态检测技术综述[J]. 电气技术, 2019, 20(3): 1-6. [7] 穆龙, 兰生, 黄明亮. 不同类型电热应力下变压器油纸绝缘老化特性实验研究[J]. 电气技术, 2018, 19(12): 29-34. [8] 廖瑞金, 杨丽君, 郑含博, 等. 电力变压器油纸绝缘热老化研究综述[J]. 电工技术学报, 2012, 27(5): 1-12. [9] 唐超, 廖瑞金, 黄飞龙, 等. 电力变压器绝缘纸热老化的击穿电压特性[J]. 电工技术学报, 2010, 25(11): 1-8. [10] 朱思瑞, 刘洋, 阮羚, 等. 环氧树脂浇注类绝缘管型母线易发缺陷分析及检测手段[J]. 电工技术学报, 2019, 34(12): 2664-2670. [11] Insulation Test Instruction for Insulation Flange qualification[R]. ITER Internal Document, IDM_ V9XYQY_v1.3. [12] Song Yuntao, Lu Kun, Huang Xiongyi, et al.Status of design and R&D for the ITER feeder system pro- curement in China[J]. IEEE Transactions on Applied Superconductivity, 2012, 22(3): 4800404. [13] Huang Xiongyi, Song Yuntao, Lu Kun, et al.High voltage test of ITER feeder components under paschen condition[J]. IEEE Transactions on Applied Super- conductivity, 2012, 22(3): 7701004. |
|
|
|