Research on entry and exit strategy of midpoint voltage divider in receiving side of Qingyu HVDC |
LIU Kai, ZOU Qiang, ZHANG Qingwu, XIAO Jianmin, LIU Xiaohui |
NR Electric Co., Ltd, Nanjing 211102 |
|
|
Abstract The receiving side of Qingyu HVDC is hierarchically connected to two 500kV AC grid, which has spilt and closed loop opera-tion modes. HVDC system needs to be compatible with hierarchical and non-hierarchical control modes. This paper intro-duced AC/DC power grid structure characteristics of Qingyu HVDC, analyzed the influence of DC midpoint voltage divider fault on HVDC and the shortage of existing coping strategies. Then, the entry & exit strategy of midpoint voltage divider which can adapt to the structure characteristics of Qingyu HVDC is proposed. At the same time, the risk of HVDC operation caused by long-term use of calculated value of control system after mid-point voltage divider fault is avoided. It also solves the problem of long-time block of the converter after non-electric protection action of midpoint voltage divider, and improves the available rate of HVDC operation.
|
Received: 18 September 2020
|
|
|
|
Cite this article: |
LIU Kai,ZOU Qiang,ZHANG Qingwu等. Research on entry and exit strategy of midpoint voltage divider in receiving side of Qingyu HVDC[J]. Electrical Engineering, 2021, 22(4): 20-25.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2021/V22/I4/20
|
[1] 俞翔, 陈乐, 邹强, 等. 特高压直流单换流器退出引起过压问题的分析及优化[J]. 电力工程技术, 2018, 37(6): 145-150, 155. [2] 刘凯, 张庆武, 侍乔明. 灵绍±800kV特高压直流协调频率控制功能应用[J]. 电力工程技术, 2018, 37(4): 14-20. [3] 卢东斌, 王永平, 王振曦, 等. 分层接入方式的特高压直流输电逆变侧最大触发延迟角控制[J]. 中国电机工程学报, 2016, 36(7): 1808-1816. [4] 吴彦维, 李晔, 陈大鹏, 等. 10000MW特高压直流工程受端分层接入交流电网方式下直流控制系统研究[J]. 电力系统保护与控制, 2015, 43(18): 108-113. [5] 郝文斌, 张振华, 单浩东, 等. 受端分层接入的特高压直流系统无功控制策略分析[J]. 山东电力技术, 2019, 46(2): 6-9. [6] 郭虎锋, 张五悦, 刘霄, 等. 锡盟—泰州特高压直流输电工程受端串联阀组中点分压器电压采集异常解决策略[J]. 电气技术, 2020, 21(6): 73-77. [7] 郭宏光, 吴彦维, 陈大鹏, 等. 分层接入方式下锡泰特高压直流输电系统阀组电压平衡控制[J]. 电力系统自动化, 2019, 43(2): 176-181. [8] 王永平, 卢东斌, 王振曦, 等. 适用于分层接入的特高压直流输电控制策略[J]. 电力系统自动化, 2016, 40(21): 59-65. [9] 黄志岭, 邹强, 卢东斌. 分层接入下绝对最小滤波器不满足回降功率策略研究[J]. 电力工程技术, 2019, 38(6): 84-92. [10] 谢季平, 张文, 杨浩. 特高压直流分层接入下交直流系统中长期电压稳定协调控制[J]. 电力系统自动化, 2020, 44(6): 37-44. [11] 李新年, 陈树勇, 李凤祁, 等. 特高压直流分层接入方式下预防换相失败的优化措施[J]. 中国电机工程学报, 2018, 38(22): 6563-6572. [12] 陶瑜. 直流输电控制保护系统分析及应用[M]. 北京: 中国电力出版社, 2015. [13] 李兴源. 高压直流输电系统的运行和控制[M]. 北京: 科学出版社, 1998. [14] 张庆武, 王永平, 陈小军, 等. 特高压直流控制保护系统设计与开发[J]. 电力系统自动化, 2013, 37(21): 88-93. [15] 蒲莹, 厉璇, 马玉龙, 等. 网侧分层接入500kV/1000kV交流电网的特高压直流系统控制保护方案[J]. 电网技术, 2016, 40(10): 3081-3087. [16] 熊凌飞, 蒲莹, 张进, 等. 受端分层接入特高压直流系统中点分压器故障控制保护策略研究[J]. 电网技术, 2018, 42(12): 4006-4014. |
|
|
|