Analysis of jumper failure of excitation system in a hydroelectric plant |
JIANG Wei |
Guangxi Guangtou Intelligent Technology Limited Company, Nanning 530200 |
|
|
Abstract In this paper, an accident that the de-excitation resistance is seriously burned out during excitation which leads to shutdown is analyzed. Through a series of tests to simulate the excitation shutdown process of the unit, it is proved that the fault is caused by the defects of the mechanical jumper in the actual operation. Finally, in order to prevent such accidents from happening again, relevant technical suggestions are put forward to ensure the safe and stable operation of the excitation system.
|
Received: 27 January 2021
|
|
|
|
[1] 广州擎天电气控制实业有限公司. EXC9000励磁系统用户手册[Z]. 2016. [2] 李开鑫, 翟保豫, 冯斌. 一起灭磁电阻柜烧毁事故的分析[J]. 电气技术, 2018, 19(2): 120-122. [3] 郭凯华, 丁宁. 从一起机组跳闸事件谈灭磁时序优化[J]. 设备管理与维修, 2018(16): 50-51. [4] 杨维平, 赵海峰, 王健. UNITROL6800励磁系统灭磁单元维护实践与分析[J]. 电工技术, 2017(5): 90-91. [5] 刘喜泉, 陈小明. 溪洛渡水电站左岸励磁系统灭磁回路工作原理及设计[J]. 水电自动化与大坝监测, 2012(2): 36-39. [6] 顾建嵘. 一种灭磁回路跨接器的新型检测方法[J]. 华电技术, 2016(8): 25-27. [7] 陈宙. 微机保护装置防跳和断路器机构防跳的探讨及配合[J]. 城市建设理论研究, 2011(22): 95-104. [8] 向秋芳, 刘喜泉, 封孝松, 等. 自并励励磁空载过电压保护研究[J]. 水电站机电技术, 2015(6): 11-13. [9] 康逸群, 宋梦琼, 宋杨. 1080MW汽轮发电机转子内部短路故障分析[J]. 电气技术, 2021, 22(2): 42-47. [10] 发电机灭磁及转子过电压保护装置技术条件第1部分磁场断路器: DL/T 294 DL/T 294.1—2011[S]. 北京: 中国电力出版社, 2011. [11] 李冠. 基于模糊控制的电除尘器电压系统的研究[D].保定: 河北大学, 2013. |
|
|
|