Analysis of Integrated Lightning Protection on Transmission Line |
Zheng Ting, Wang Jianxin, Liu Jianguo |
Xuejiawan Power Supply Bureau, Ordos, Inner Mongolia 010300 |
|
|
Abstract Xue jia wan area is located in hilly land, gully aspect and the environment is bad, the annual average thunderstorms rate is higher, which belongs to many mine areas, The transmission line in this area occurs lightning trip-out failure frequently in recent years, which harms to the safety and stable operation of the transmission line seriously, for the region’s power grid caused serious harm. This paper researches and analyzes the high trip rate of ZhunGeEr area transmission line, it is resulted by lightning strike, and find out rectification measures about avoiding lightning strike so as to effectively reduce the region’s lightning trip-out rate ang this measures accord with the actual application of ZhunGeEr region.
|
Received: 26 June 2014
|
|
|
|
Cite this article: |
Zheng Ting,Wang Jianxin,Liu Jianguo. Analysis of Integrated Lightning Protection on Transmission Line[J]. Electrical Engineering, 2013, 14(5): 103-103.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2013/V14/I5/103
|
[1] 余世峰, 等.同塔双回输电线路绕击耐雷性能[J].高压技术, 34(1).2008:23-26. [2] 曹志煌, 等.浅谈绕击率与保护角、坡度的关系[J].高压技术, 2006, 32(11):174-175. [3] 李景禄, 胡毅, 刘春生.实用电力接地技术[M].北京:中国电力出版社, 2002:64-65, 206-218. |
|
|
|