Research on 100% Steam-driven Pump Runback Test of 300MW Subcritical Unit |
Zou Baochan, Han Qiuxi, Li Yun |
China Datang Corporation Science and Technologic Research Institute Co., Ltd, Northwest Branch, Xi’an 710065 |
|
|
Abstract About the 100% steam-driven Pump and 50% motor-driven Pump of 300MW unit feedwater system, the design completed the steam-driven Pump runback control scheme for ensuring the unit main parameters in the range allowed, And then the RB test of steam-driven Pump is completed successfully and it gave some valuable references for the similar unit.
|
Published: 02 June 2015
|
|
|
|
[1] 胡雄辉. 300MW亚临界机组100%容量汽泵RB试验研究[J]. 湖南电力, 2008, 28(5): 14-16. [3] 高春雨, 周倩, 杨尚. 亚临界300MW机组RB控制策略优化[J]. 热力发电, 2013, 42(9): 121-124. |
|
|
|