													    | Abstract  Low-voltage VFD is sensitive to voltage fluctuation. Because of voltage dips, unplanned stop of VFD happened frequently. This paper made deep research on DC-Bank scheme and restart scheme of VFD anti-electricity shaking, analyzed problems of common solutions, and proposed a relevant solution. The conclusion of this paper has a certain significance to the choice of anti-electricity shaking scheme of low-voltage VFD. |  