Live detection and analysis of internal parts looseness of 550kV gas insulated switchgear |
Song Dongbo1, Huang Jie2, Yang Wei1, Qin Shaorui1, Zhang Guobao1 |
1. State Grid Anhui Electric Power Company Limited Research Institute, Hefei 230022; 2. State Grid Anhui Electric Power Company Limited Training Center, Hefei 230022 |
|
|
Abstract Live detection can detect potential defects of equipment in time. It is one of the important means to evaluate the running state of equipment. Detection and analysis of some internal parts looseness defects in 550kV gas insulated switchgear (GIS) are introduced. The defects are diagnosed and located by ultrasonic method, ultra-high frequency method partial discharge technology and X-ray imaging technology. Disassembly inspection confirms that the defects are caused by the loosening or falling off of the fastening bolt of the particle trap in GIS.
|
Received: 27 March 2019
Published: 19 November 2019
|
|
|
|
Cite this article: |
Song Dongbo,Huang Jie,Yang Wei等. Live detection and analysis of internal parts looseness of 550kV gas insulated switchgear[J]. Electrical Engineering, 2019, 20(11): 112-116.
|
|
|
|
URL: |
https://dqjs.cesmedia.cn/EN/Y2019/V20/I11/112
|
[1] 邱毓昌. GIS装置及其绝缘技术[M]. 北京: 水利电力出版社, 1994. [2] 李军浩, 韩旭涛, 刘泽辉, 等. 电气设备局部放电检测技术述评[J]. 高电压技术, 2015, 41(8): 2583-2601. [3] 张欣, 李高扬, 黄荣辉, 等. 不同运行年限的GIS缺陷率统计分析与运维建议[J]. 高压电器, 2016, 52(3): 184-188, 194. [4] 宁宇, 孙洪宇, 张伟, 等. GIS高压母线段间连接缝隙造成的过热分析[J]. 电工技术学报, 2017, 32(S1): 217-224. [5] 宋东波, 黄洁, 朱太云, 等. 一起GIS固体绝缘件局部放电缺陷的定位与分析[J]. 高压电器, 2018, 54(5): 74-79. [6] 唐志国, 刘江明, 郦于杰, 等. GIS局放状态检测策略研究[J]. 高压电器, 2018, 54(11): 41-47. [7] 王国利, 高超, 杨芸, 等. GIS绝缘缺陷局部放电检测的有效性研究[J]. 高压电器, 2018, 54(11): 62-72. [8] 罗翔. 一起基于声电联合检测的特高压GIS断路器局部放电缺陷诊断分析与处理[J]. 电气技术, 2018, 19(6): 107-111, 116. [9] 申强, 杨海龙, 刘航, 等. 超声波局部放电检测技术在500kV GIS盆式绝缘子上颗粒缺陷诊断中的应用[J]. 高压电器, 2017, 53(9): 228-233. [10] 黎慧明, 张志磊. GIS局部放电测试案例分析[J]. 电气技术, 2018, 19(11): 111-114. [11] 冯新岩, 赵延志, 杨乘龙, 等. GIS超声波局放检测现场典型干扰分析[J]. 高压电器, 2018, 54(10): 241-245. [12] 宋东波, 秦少瑞, 陈凡, 等. 几起GIS绝缘件局部放电缺陷的检测与分析[J]. 高压电器, 2018, 54(11): 153-159. [13] 陈晓琳, 赵天成, 陈林聪, 等. GIS设备局部过热故障程度与SF6分解的关联特性[J]. 高压电器, 2018, 54(11): 109-115. [14] 唐炬, 杨东, 曾福平, 等. 基于分解组分分析的SF6设备绝缘故障诊断方法与技术的研究现状[J]. 电工技术学报, 2016, 31(20): 41-55. [15] 许焕清, 马君鹏, 王成亮, 等. GIS设备典型缺陷的X射线数字成像检测技术[J]. 电网技术, 2017, 41(5): 1697-1702. [16] 马飞越, 王沛, 王博. GIS母线支撑绝缘子气隙放电综合诊断与分析[J]. 高压电器, 2018, 54(11): 147-152. [17] 雷汉坤, 贾志杰. 检测GIS固体绝缘内部放电缺陷的特高频和X射线数字成像联合方法研究[J]. 高压电器, 2018, 54(1): 224-229. [18] 闫斌, 何喜梅, 王志惠, 等. X射线数字成像检测系统在GIS设备中的应用[J]. 高压电器, 2010, 46(11): 89-91. |
|
|
|