Case analysis of direct current equipment frame protection malfunction in subway |
SHEN Cikui |
Xiamen Metro Operation Co., Ltd, Xiamen, Fujian 361000 |
|
|
Abstract DC equipment is very important in power supply system of subway, which directly affects the driving and metro operation. When the DC bus encounters a shell collision fault, it can quickly cut off fault current by setting frame protection to ensure the safety of the person and the equipment. In this paper, by introducing the principle and function of frame protection, optimization solutions are explored to reduce the probability of malfunction through case studies.
|
Received: 21 November 2024
|
|
|
|
[1] 刘炜, 娄颖, 张戬, 等. 计及城市轨道交通逆变回馈装置的交直流统一供电计算[J].电工技术学报, 2019, 34(20): 4381-4391. [2] 潘雷, 荀浩. 地铁再生制动能馈装置分站设置研究[J].电气技术, 2020, 21(10): 59-62. [3] 黄德胜, 张巍. 地下铁道供电[M].北京: 中国电力出版社, 2010. [4] 于松伟, 杨兴山, 韩连祥, 等. 城市轨道交通供电系统设计原理与运用[M].成都: 西南交通大学出版社, 2008. [5] 李昕, 范庆平. 地铁牵引供电直流设备框架保护系统改进[J].铁道技术监督, 2023, 51(1): 50-54. [6] 刘建华. 一起牵引变电所框架保护跳闸事故的分析[J].机电工程技术, 2021, 50(4): 263-264. [7] 王小峰. 地铁直流框架泄漏保护的优化设计[J].电气化铁道, 2015(2): 31-34. [8] 陈民武, 赵鑫, 丁大鹏, 等. 城市轨道交通供电系统钢轨电位限制装置操作过电压研究[J].中国铁道科学, 2017, 38(6): 94-98. [9] 地下铁道工程施工质量验收标准: GB/T 50299—2018[S].北京: 中国建筑工业出版社, 2018. [10] 张征, 杨少兵, 吴命利, 等. 一种用于钢轨电位评估的回归建模方法[J].电工技术学报, 2021, 36(增刊1): 31-39. [11] 刘炜, 杨龙, 李国玉, 等. 计及回流系统设备行为过程的钢轨电位动态仿真[J].电工技术学报, 2022, 37(4): 1000-1009. [12] 金文辉. 地铁车辆段杂散电流分析与防护方案[J].电气技术, 2023, 24(2): 11-17. |
|
|
|