| Analysis on a wiring misconnection hazard in the close position monitoring circuit |
| ZHANG Hui1, CHEN Hao2, YAO Jinming1 |
1. UHV Company of State Grid Jiangsu Electric Power Co., Ltd, Nanjing 211102; 2. Nanjing Power Supply Company, State Grid Jiangsu Electric Power Co., Ltd, Nanjing 210019 |
|
|
|
|
Abstract The position monitoring circuit is capable of reflecting the position status of the circuit breaker and the integrity of the trip and close circuits, playing a crucial monitoring role in the circuit breaker's control circuit. This paper addresses a potential hazard in a 1 000 kV ultra-high voltage substation where the C-phase trip circuit monitoring wire of the circuit breaker is incorrectly connected. A theoretical analysis is conducted on the wiring methods of the position monitoring and control circuit disconnection signal circuits, highlighting that most current hazards are related to power loss, with insufficient awareness of long-term energized hazards that may lack alarm indications. Furthermore, the coordination between the conventional trip position monitoring circuit and the circuit breaker's anti-pump circuit is discussed, elucidating the rationality of their coordination under different scenarios. Lastly, based on the hazard investigation, suggestions for improvement in the acceptance of infrastructure and technical renovation projects are proposed.
|
|
Received: 25 February 2025
|
|
|
|
| Cite this article: |
|
ZHANG Hui,CHEN Hao,YAO Jinming. Analysis on a wiring misconnection hazard in the close position monitoring circuit[J]. Electrical Engineering, 2025, 26(10): 69-74.
|
|
|
|
| URL: |
|
https://dqjs.cesmedia.cn/EN/Y2025/V26/I10/69
|
[1] 单国栋. 一起110kV断路器偷跳引起的10kV备自投装置拒动事故分析[J]. 电气技术, 2024, 25(6): 77-81. [2] 陈昊, 刘怀宇, 姚凯, 等. 采用自补偿复合电流判据的变电站长段动力电缆漏电监测方法[J]. 电力系统保护与控制, 2022, 50(12): 172-179. [3] 张卓杰, 陈俊宇, 王雨晨, 等. 南方电网某换流站线路开关控制回路的设计缺陷及改造方案分析[J]. 电工技术, 2022(18): 86-88. [4] 吕航, 龚啸, 丁杰, 等. 基于二次回路建模的保护运维技术[J]. 电气技术, 2023, 24(6): 64-68. [5] 肖博峰. 500 kV断路器操动机构二次回路典型缺陷及优化建议[J]. 四川电力技术, 2021, 44(6): 85-91. [6] 常俊晓, 应宇鹏, 马秀林, 等. 断路器控制回路缺陷在线分析装置的研制[J]. 湖北电力, 2022, 46(1): 95-100. [7] 徐涛, 仇前生, 陆振坤, 等. 断路器防跳回路的应用分析及改进设计[J]. 电工电气, 2022(4): 67-69. [8] 赵小兵. 断路器机构防跳下的合闸回路监视回路[J]. 云南电力技术, 2024, 52(3): 76-79. [9] 徐胜蓝, 陈昊, 涂腾, 等. 高压断路器防跳回路相关优化试验方法[J]. 四川电力技术, 2024, 47(3): 95-100. [10] 高远, 刘怀宇, 赵睿. 一起断路器防跳回路缺陷案例的分析及改进方法[J]. 电工电气, 2021(4): 34-37, 47. [11] 杨远航, 虎啸, 解良, 等. 具备自监视功能的“断路器控制回路断线告警”信号回路设计[J]. 云南电力技术, 2024, 52(1): 70-74. [12] 管彦赛. 500 kV智能变电站断路器控制回路断线异常分析[J]. 电工电气, 2023(11): 72-74. [13] 国家电网有限公司安全事故调查规程 (内部文件)[Z].国家电网有限公司安全事故调查规程 (内部文件)[Z]. 国家电网有限公司, 2021. [14] 孟庆萌, 李瑞, 白瑞, 等. 防跳回路检验与监视方法[J]. 山西电力, 2024(5): 47-49. [15] 陈昊, 廖英祺, 张连芹, 等. 基于自适应滤波的信号分离与窄带干扰抑制[J]. 电力工程技术, 2019, 38(2): 129-134. [16] 曾香平, 肖佳朋, 谭羽辰, 等. 断路器防跳回路原理及验收试验[J]. 电工技术, 2024(21): 192-194, 203. [17] 王海波. 断路器分位防跳失败原因分析与整改措施[J]. 电气技术, 2022, 23(9): 81-85. [18] 华东电网500kV继电保护工程设计审查要点(试行稿)[Z].华东电网500kV继电保护工程设计审查要点(试行稿)[Z]. 国网华东电力调控分中心, 2017. [19] 宋小欣, 魏艺君, 熊守江. 断路器防跳回路辅助触点的应用与探讨[J]. 江西电力, 2023, 47(5): 37-39, 43. |
|
|
|