Abstract In order to ensure the manufacturing quality of the stator coils of the 530 MW Russian- made unit renovation project of Panshan power plant, this paper analyzes the key manufacturing technology for the stator coils and proposes technical measures to solve the problems. This article adopts technical measures form the control technology of multi-structure coil end shape and the optimization of the main insulation pressing process, such as the establishment of a control system for the shape of the stator coil end, the modular design and manufacturing of the hot press molding, the optimization of the coil cooling anti-deformation device, the optimization of the anti-glue flow process during the pressing of the stator coil straight section, and the optimization of the coil surface treatment process, which solve technical problems of large geometric dimensional deviation at the end of the stator coil and insulation cavitation during the pressing of the main insulation. A high-precision manufacturing system suitable for large water-cooled stator coils is established, which provides an important technical reference for the renovation of similar large generators. The research results shows that the initial value of the dielectric loss factor of the stator coils of the Panshan renovation generator is less than 1%, the increment of the dielectric loss factor is less than 0.5%, and the breakdown voltage is greater than 110 kV (5.5 times the rated voltage). The electrical properties of the stator coils satisfy the industry standards requirements.
|
|
Received: 08 September 2025
|
|
|
|
| Cite this article: |
|
MA Wenhao,SUN Changtai,SUN Changquan等. Research on key manufacturing process of water-cooled stator coils for the 530 MW renovation generator of Panshan power plant[J]. Electrical Engineering, 2026, 27(4): 76-79.
|
|
|
|
| URL: |
|
https://dqjs.cesmedia.cn/EN/Y2026/V27/I4/76
|
[1] 赵立春. 清河发电有限责任公司4号机组振动分析及治理[J]. 电力设备, 2007(1): 71-73. [2] 王思宇, 周凯, 朱光亚, 等. 一种基于极化电流和脱陷电流的发电机定子线棒主绝缘劣化表征方法[J]. 电工技术学报, 2025, 40(1): 285-299. [3] 陈枰. 1号机组定子绝缘盒内环氧胶开裂、脱落缺陷分析与处理[J]. 电气技术与经济, 2022(4): 155-157. [4] 申雁鹏, 王声学. 10kV箱变改造为发电机转子护环感应加热电源的研究与应用[J]. 电气技术, 2024, 25(4): 72-76. [5] 严勇. 水轮发电机定子线圈绝缘损坏的处理与增容改造措施[J]. 通信电源技术, 2019, 36(6): 100-101. [6] 付国宏, 秦风斌, 李文金, 等. 葛洲坝电厂19号机组改造增容分析[J]. 水电与新能源, 2019, 33(11): 75-78. [7] 杨宝锋, 袁林, 周厚雄, 等. 月江水电站水轮发电机定子技术改造[J]. 电力系统装备, 2024(11): 149-151. [8] 孔维星, 李娟. 汽轮发电机稳定运行时定子端部绕组的应力分析[J]. 电气技术, 2016, 17(4): 29-34. [9] 付强, 满宇光, 卢春莲, 等. 大型电机VPI绝缘体系的关键技术研究[J]. 电气技术, 2016, 17(2): 1-8. [10] 吴东东, 李娟. 大型汽轮发电机定子绕组三维模型建立及模态分析[J]. 电气技术, 2018, 19(4): 5-9, 27. [11] 胡波, 梁智明, 漆临生, 等. 电极系统对电机定子线棒绝缘介质损耗的影响[J]. 电气技术, 2011, 12(1): 13-17. |
|
|
|