Abstract:Due to the randomness of the renewable energy, high penetration of wind and photovoltaic power generation will bring a series of problems such as frequency fluctuations. A large number of Plug-in electric vehicles (PEVs) and controllable loads have been shifting into focus for this. A dynamic vehicle-to-grid (V2G) model with feedback control is proposed by considering the battery charging/discharging characteristics and the dynamic model of frequency regulation with PEVs and controllable loads for a single area is established. Simulation results demonstrate that the application of PEVs and controllable loads can relief the frequency refutation due to the randomness of renewable energy sources.
刘保平, 杨洪明. 电动汽车及可中断负荷参与电网的调频控制[J]. 电气技术, 2013, 14(5): 10-13.
Liu Baoping, Yang Hongming. PEVs and Interruptible Loads for Frequency Regulation. Electrical Engineering, 2013, 14(5): 10-13.
[1]BOULAXIS N G, PAPATHAMTSSIOU S A, Papadopoulos MP. Wind turbine effect on the voltage profile of distribution networks[J]. Renewable Energy, 2002, 25(3): 401-415. [3]LAWRENCE E O, HEFFNER G, GOLDMAN C, KINTNER-MEYER M, KIRBY B.Technical Appendix: Market Descriptions, 2007. [4] KEMPTON W, DHANJU A. Electric vehicles with V2G: storage for large-scale wind power[J]. Windtech International, 2006, 2(5): 18-21. [5] KEMPTON W, LETENDRE S. Electric vehicles as a new power source for electric utilities[J]. Transportation Research (Part D), 1997, 2(3): 157-175. [6] KEMPTON W, TOMIC J. Vehicle-to-grid power implementation: from stabilizing the grid to supporting large-scale renewable energy[J]. Journal of Power Sources, 2005, 144(1): 280-294. [7] KEMPTON W, DHANJU A. Electric vehicles with V2G: storage for large-scale wind power[J]. Windtech International, 2006, 2:18–21. [8] KONDOH J. Autonomous frequency regulation by controllable loads to increase acceptable wind power generation [J]. Wind Energy, 2010, 13(6): 529–541. [9] PILLAI J R, BAK-JENSEN B. Integration of Vehicle- to-Grid in the Western Danish power system[J]. IEEE Transaction on Sustainable Energy, 2011, 2(1): 12-19. [10] SALAMEH Z M, CASACCA M A, LYNCH W A. A mathematical model for lead-acid batteries [J]. IEEE Trans on Energy Conversion, 1992, 7(1): 93-98. [11] LU C F, LIU C C, WU C J. Effect of battery energy storage system on load frequency control considering governor deadband and generation rate constraint[J]. IEEE Trans. on Energy Conversion, 1995, 10(3): 555-561. [12] Manual of Electric Water Heaters—Plan, Design, & Execution. Extra Issue of Amenity & Electri? cation, Japan Industrial Publishing Co, 1999-3. [13] Advanced Transport Systems Ltd. "ULTra PRT, " Jun. 2010. [OL]. Available: http://www.ultraprt.com/.