Abstract:A new method is proposed for analysis of make-up electric power during voltage loss of the electric energy meter based on the power user electric energy data acquire system. The article introduced the voltage loss of the three-phase electric energy meter and the traditional calculation method of make-up electric power of the three-phase four-wire meter. In view of shortcomings of the existing way, a new method based on the power user electric energy data acquire system was presented, also, its mathematical model and an application example was devised. This method can highly improve the accuracy of make-up power of three-phase electric energy meter during voltage-loss and be helpful for work of make-up electric energy.
王海涛, 胡元璐. 基于用电信息采集系统的电能表失压断相后电量追补的分析[J]. 电气技术, 2017, 18(8): 56-58.
Wang Haitao, Hu Yuanlu. The Analysis of Make-up Electric Power During Voltage Loss of the Electric Energy Meter based on the Power User Electric Energy Data Acquire System. Electrical Engineering, 2017, 18(8): 56-58.