电气技术  2017, Vol. 18 Issue (3): 131-135    DOI:
技术与应用 |
M701F型联合循环机组汽轮机旁路阀执行器改造浅析
李东
深圳能源集团股份有限公司东部电厂,广东 深圳 518120
Analysis of Steam Turbine Bypass Valve Actuator in M701F Combine Cycle Power Plant
Li Dong
Shenzhen Energy Group Co., Ltd, Dongbu Power Plant, Shenzhen, Guangdong 51812
全文: PDF (5363 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 本文对汽轮机旁路阀的常发性故障作了简要分析和总结,针对故障原因提出了旁路阀执行器的改造方案,并对改造过程中所遇到的问题及处理方法进行了详细地阐述。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
李东
关键词 燃气轮机汽轮机旁路系统智能执行器锅炉水位    
Abstract:Turbine bypass valve is an important part of Steam Turbine playing an important role when the units start and stop. For the gas turbine combined cycle unit that is particularly important fully automatic bypass system. This article analyzes and concludes the hazards of turbine bypass valve and proposing an optimization program. The problems encountered in the process of transformation and the treatment methods are described in detail.
Key wordsgas turbine    bypass system of steam turbine    intelligent actuator    boiler level   
     出版日期: 2017-03-21
作者简介: 李 东(1981-),男,技术工程师,现从事燃气轮机发电厂检修安全管理工作。
引用本文:   
李东. M701F型联合循环机组汽轮机旁路阀执行器改造浅析[J]. 电气技术, 2017, 18(3): 131-135. Li Dong. Analysis of Steam Turbine Bypass Valve Actuator in M701F Combine Cycle Power Plant. Electrical Engineering, 2017, 18(3): 131-135.
链接本文:  
http://dqjs.cesmedia.cn/CN/Y2017/V18/I3/131