|
|
Research of Bird-related Transmission Line Trip-out Precautions |
Fu Hao1, Zhang Dong2, Dong Xinsheng2, Chen Yanchao3, Wang Lifu1 |
1. State Grid Electric Power Company of Xinjiang, Urumqi 830011; 2. State Grid Electric Power Research Institute of Xinjiang Electric Power Company, Urumqi 830011; 3. State Grid Electric Power Company Urumqi Xinjiang Power Company, Urumqi 830011 |
|
|
Abstract With the implementation of strengthening people's awareness of environmental protection and return grass after returning farmland to forest policy, the number of birds has also increased, also causing transmission line failures involving birds is increasing. To reduce the transmission line failure in the study of birds involved, it is being taken more bird tailgate umbrella group, bird thorn, insulated jacket and intelligent bird and other various anti-bird measures against these anti-bird measures on only through the theoretical research, for field installation options and how to meet the few studies, resulting in many places, although the comprehensive anti-bird measures taken, but there are cases of failure involving birds. By analyzing the causes of different anti-bird measures fail, come in only when prevention larger body of birds, can only use anti-bird thorn bird thorn shelter but scope should meet the requirements of anti-bird; in the use of anti-bird baffle, bird baffles inclined not tilt direction along the wire. If taken in addition to other outside bird thorn bird measures, other anti-bird measures must be combined with anti-bird thorn bird use in order to achieve comprehensive results.
|
Published: 22 March 2016
|
|
|
|
Cite this article: |
Fu Hao,Zhang Dong,Dong Xinsheng等. Research of Bird-related Transmission Line Trip-out Precautions[J]. Electrical Engineering, 2016, 17(3): 132-135.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2016/V17/I3/132
|
[1] 王峰, 黄福勇, 曾昊, 等. 湖南省输电线路鸟害障碍分析及防治[J]. 高压电器, 2011, 47(10): 97-101, 105. [2] 易辉, 熊幼京, 周刚, 等. 架空输电线路鸟害故障分析及对策[J]. 电网技术, 2008, 32(20): 95-100. [3] 王少华, 叶自强. 架空输电线路鸟害故障及其防治技术措施[J]. 高压电器, 2011, 47(2): 61-67. [4] 梁曦东, 黄崚, 王绍武, 等. 合成绝缘子鸟粪闪络与不明原因闪络[J]. 电网技术, 2001, 25(1): 13-16. [5] Zhou Y X, Xu X, Nie Q, et al. Bird streamer caused flashover in EHV transmission line[J]. IEEE Trans- actions on Dielectrics and Electrical Insulation, 2009, 16(1): 69-76. [6] Sundararajan R, Burnham J, Carlton R, et al. Preventive measures to reduce bird related power outage-part II: steamers and contamination[J]. IEEE Transactions on Power Delivery, 2004, 19(4): 1848- 1853. [7] 贾雷亮. 输电线路鸟粪闪络特点及防范措施分析[J]. 电力设备, 2006, 7(11): 27-28. [8] 黎卫国, 郝艳捧, 熊国锟, 等. 覆冰复合绝缘子电位分布有限元仿真[J]. 电工技术学报, 2012, 27(12): 29-35. [9] 薛彬, 范利江, 藏国民. 预防超高压线路鸟害故障的措施[J]. 电网技术, 2008, 32(S1): 157-158. [10] 李孛, 许圣, 苏伟. 220kV输电线路不明原因跳闸事故分析[J]. 电瓷避雷器, 2011(3): 10-15. |
|
|
|