Design of Monitoring System for Operating Environment in Substation 10kV Breaker Cabinet |
Chen Weifan1, Chen Xiaoliang2, Gao Wei1 |
1. College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350116; 2. Fujian Lianjiang Electric Power Supply Co., Ltd, Fuzhou 350500 |
|
|
Abstract It is difficult to acquire and control real-timely the situation of fire clay blocking, temperature, and humidity in substation 10kV breaker cabinet. To decline the risks of this situation, a monitoring system for substation 10kV breaker cabinet is designed. The network architecture of this system is composed with wireless sensor network and Ethernet. Every monitoring terminal device has an information exchange with communication manager via wireless sensor network. And Ethernet is used to communicate with host computer for communication manager. In this paper, not only the design of hardware and software but also parameter configuration of wireless sensor are introduced in detail, related to the special operating environment of substation 10kV breaker cabinet.
|
Received: 22 September 2016
Published: 22 September 2016
|
|
|
|
Cite this article: |
Chen Weifan,Chen Xiaoliang,Gao Wei. Design of Monitoring System for Operating Environment in Substation 10kV Breaker Cabinet[J]. Electrical Engineering, 2016, 17(9): 83-87.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2016/V17/I9/83
|
[1] 陈雪薇, 马国明, 李成榕, 等. 高压开关柜无线测温系统设计及可靠性研究[J]. 高压电器, 2015, 51(6): 152-160. [2] 刘朝霞. 高压开关柜无线测温系统设计[J]. 电力安全技术, 2015, 17(7): 40-42. [3] 王健, 刘忱. ZigBee组网技术的研究[J]. 仪表技术, 2008(4): 10-12. [4] 郭谋发. 采用WSN技术的配电开关柜无线测温系统[J]. 福州大学学报(自然科学版), 2011, 39(3): 415-421. [5] 陈静洁, 蔡奕龙, 高伟, 等. 基于WSN和露点控制的开关柜防潮系统研制[J]. 电气应用, 2015(14): 97-101. [6] 李小江, 郭谋发, 高伟. 用于低压配网负荷及漏电流监控的通信管理机研制[J]. 电工电气, 2014(5): 18-22. [7] 黄世远, 杨如辉, 郭谋发, 等. 配电网自动化通信规约转换器的设计[J]. 电气技术, 2010(7): 28-33. [8] 王奉武. 上位机设计技术剖析[J]. 山东工业技术, 2015(16): 195, 269. |
|
|
|