The Analysis and Countermeasure of AC Filter Abnormal Switching in Xi-Zhe HVDC Project |
Ai Hongjie1, Wang Yatao1, Xiong Fei1, Jin Hongjie2, Wang Yong2 |
1. XJ Electric Corp. Ltd, Xuchang, He’nan 461000; 2. The First company of China Eighth Engineering Bureau, Ltd, Zhengzhou 450000 |
|
|
Abstract AC filter can provide reactive power and harmonics in HVDC transmission project, which can ensure the normal starting and stopping of the converter, the bus voltage stability and the power quality. In this paper, a case study is made on the investment of the AC filter in the river and the project. The reasons of the abnormal investment and the investment are analyzed. The operation of the field shows that the optimized AC filter is normal, and the system running stably and reliably.
|
Published: 23 May 2017
|
|
|
|
Cite this article: |
Ai Hongjie,Wang Yatao,Xiong Fei等. The Analysis and Countermeasure of AC Filter Abnormal Switching in Xi-Zhe HVDC Project[J]. Electrical Engineering, 2017, 18(5): 92-96.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2017/V18/I5/92
|
[1] 特高压直流电工程直流站控设计规范[Z]. 许继集团直流输系统公司, 2011. [2] 赵畹君. 高压直流输电工程技术[M]. 2版. 北京: 中国电力出版社, 2011. [3] 贾轩涛, 严兵, 张爱玲, 等. 锦屏—苏南±800kV特高压直流工程交流滤波器投入异常分析和应对措施[J]. 电力建设, 2013, 34(3): 92-97. [4] 姚进波, 贾轩涛, 周玉勇, 等. 特高压工程DCC800直流保护与控制配合逻辑分析[J]. 南方电网技术, 2013, 7(4): 78-82. [5] 戴国安, 周君文, 王亚非. 特高压直流无功控制策略研究[J]. 电力系统保护与控制, 2008, 36(14): 48-51. [6] 张望, 郝俊芳, 曹森, 等. 直流输电换流站无功功率控制功能设计[J]. 电力系统保护与控制, 2009, 37(14): 72-76. [7] 李延龙, 杨亚璞, 李楠. 高压直流输电控制保护系统的冗余可靠性研究[J]. 电力系统保护与控制, 2009, 37(16): 59-62. |
|
|
|