Study on anti condensation design of charging equipment for electric vehicles |
Gao Qingyong, Fang Xiangcheng, Chen Weiming, Liu Yanmin, Wang Xiaolei |
XJ Power Co., Ltd, Xuchang, He’nan 461000 |
|
|
Abstract Charging facilities for electric vehicles are directly installed outside. Condensation phenomenon would occur on the surface of charging facilities with rapidly changing of ambient temperature and humidity. The mechanism of dewing and harm of dew to electrical equipments in high humidity enviroment are studied in this paper. Four design shcemes for charging facilities are improved to solve the problem of dewing. Simulation test of condensation is accomplished by using high-low temperature chamber. The effect of four design schemes is tested and anlyzed to find the best anti condensation scheme. Safety and reliability of internal electrical equipments are effectively guaranteed. The design scheme has important guiding significance for anti condensation design of similar outdoor products.
|
Received: 29 June 2017
Published: 22 January 2018
|
|
|
|
Cite this article: |
Gao Qingyong,Fang Xiangcheng,Chen Weiming等. Study on anti condensation design of charging equipment for electric vehicles[J]. Electrical Engineering, 2018, 19(1): 50-52.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2018/V19/I1/50
|
[1] 国家发展改革委. 电动汽车充电基础设施发展指南[Z]. 2015. [2] 瞿剑. “九纵九横两环”高速公路快充网络年内建成[N]. 科技日报, 2017, 1, 23(3). [3] 朱世民, 蒋志军. 浅谈变电站端子箱凝露结霜的危害和防治[J]. 科技创新与应用, 2015(33): 210. [4] 温洪曾. 高压配电室防潮除湿方法及治理措施[J].中国新技术新产品, 2013(17): 135-136. [5] 罗宣国, 夏丽建. 电气设备的防凝露技术研究[J]. 可再生能源, 2014, 32(4): 489-492. [6] 唐洁. 变频器凝露的危害及预防措施[J]. 电气技术, 2015, 16(6): 132-134. [7] 罗林开, 周杨. 10kV电缆分支箱防凝露治理措施[J]. 电工技术, 2012(6): 58, 60. [8] YGDH—2000半导体冷凝除湿装置说明书[Z]. 保定市屹高电气有限公司, 2014. [9] XY系列智能型抽湿装置说明书[Z]. 上海贤业电气自动化设备有限公司, 2016. [10] 叶瑞, 张豪俊, 张冰冰, 等. 户外型智能控制柜凝露预防[J]. 电气技术, 2016, 17(8): 110-113. [11] 郝瑞英, 葛天舒, 代彦军. 金属表面涂覆干燥剂的防凝露研究[J]. 上海交通大学学报, 2014, 48(11): 1588-1594. [12] 周舟, 万涛, 龚尚昆, 等. 基于CFD技术的六氟化硫电气设备中气体湿度测量方法研究[C]//电工技术前沿问题学术论坛, 2014. |
|
|
|