Design of outdoor side outer insulation length of ±1100kV DC wall bushing |
Niu Wanyu, Zhou Hong, Li Min |
XJ Group Corporation, Xuchang, He’nan 461000 |
|
|
Abstract Based on the air clearance and creepage distance, the air clearance and creepage distance of the outer wall of the DC wall bushing are studied with reference to relevant literature and standards. The design principle of the outer insulation length of the DC wall bushing is given. The outer insulation length design needs to meet the requirements of air clearance and creepage distance. According to the design principle, the outdoor insulation length of the ±1100kV DC wall bushing of Changji Station is analyzed by calculating the air clearance and creepage distance. The results show that the minimum insulation length of the outdoor side of the ±1100kV DC wall bushing of Changji Station is 12.99m.
|
Received: 20 October 2019
Published: 16 April 2020
|
|
|
|
Cite this article: |
Niu Wanyu,Zhou Hong,Li Min. Design of outdoor side outer insulation length of ±1100kV DC wall bushing[J]. Electrical Engineering, 2020, 21(4): 71-75.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2020/V21/I4/71
|
[1] 刘振亚. 特高压直流电气设备[M]. 北京: 中国电力出版社, 2009. [2] 刘振亚. 特高压交直流电网[M]. 北京: 中国电力出版社, 2013. [3] 贾伟, 牛万宇, 王帮田, 等. ±1100kV直流阀厅金具电场仿真设计[J]. 电气技术, 2016, 17(7): 13-19. [4] DL/T5426—2009. ±800kV高压直流输电系统成套设计规程[S]. [5] GB/T 26218.3—2011. 污秽条件下使用的高压绝缘子的选择和尺寸确定第3部分: 交流系统用复合绝缘子[S]. [6] GB/T 16927.1—2011. 高电压试验技术第1部分: 一般定义及试验要求[S]. [7] Berggren S.-4200/800 for kV HVDC technical report, FL 1900-1700[R]. 2004. [8] 夏雪, 李宝金, 黄晓明, 等. 换流站直流侧空气净距及海拔修正计算方法[J]. 南方电网技术, 2009, 3(6): 27-29. [9] 陈锡磊, 周浩, 王东举, 等. g参数修正法用于浙西±800kV换流站阀厅空气净距设计[J]. 高电压技术, 2011, 37(9): 2185-2189. [10] 邱志斌, 阮江军, 唐烈峥, 等. 空气间隙的储能特征与放电电压预测[J]. 电工技术学报, 2018, 33(1): 185-194. [11] 张刘春. ±1100kV特高压直流输电线路防雷保护[J]. 电工技术学报, 2018, 33(19): 4611-4617. [12] 刘朋飞, 南振乐, 李振军. ±800kV气体绝缘直流穿墙套管的研制[J]. 电气技术, 2017, 18(12): 42-45, 52. [13] 刘毓, 蒋兴良, 舒立春, 等. 复合绝缘子伞裙结构特征参数对其冰闪特性的影响[J]. 电工技术学报, 2014, 29(8): 319-326. [14] 马斌. 1100kV交流SF6组合电器用空心复合绝缘子的设计及实现[J]. 电网技术, 2006, 30(12): 98-101. [15] 钟建英, 柴影辉, 王赛豪, 等. ±1100kV直流纯SF6气体绝缘穿墙套管关键技术研究[J]. 电力建设, 2017, 38(10): 129-137. [16] 樊阳文, 翁凌云, 罗苏南, 等. ±1100kV直流电子式电压互感器绝缘特性研究[J]. 高压电器, 2018, 54(6): 164-169. [17] 罗晓庆, 胡伟, 徐涛, 等. ±1100kV直流U型结构穿墙套管空气间隙放电特性及间隙距离选择[J]. 高电压技术, 2017, 43(3): 946-952. [18] 牛万宇. ±1100kV直流SF6穿墙套管伞裙结构设计[J]. 电气技术, 2019, 20(7): 18-22. [19] 周沛洪, 周文俊, 何慧文, 等. ±1100kV古泉换流站户内直流场雷电侵入波过电压和绝缘配合研究[J]. 高电压技术, 2018, 44(增刊1): 60-67. [20] 张学成, 檀金华, 牛万宇, 等. ±1100kV直流输电工程换流变压器阀侧套管的设计[J]. 高电压技术, 2012, 38(2): 393-399. |
|
|
|