Research on the lightning intruding surge protection for 500kV substation |
ZHOU Yanqing, CHEN Yang |
China Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd, Guangzhou 510663 |
|
|
Abstract This paper takes the main electrical wiring, equipment parameters, transmission tower and gantry model of the 500kV substation as the calculation input, and uses the electromagnetic transient program to simulate the lightning intrusion wave overvoltage. The maximum lightning overvoltage on the substation equipment under the typical operation mode are calculated. Afterimprovement measures are proposed. The maximum lightning overvoltage value on the transformer and other equipment is lower than the allowable value, meets the requirements of lightning protection.
|
Received: 26 July 2020
|
|
|
|
Cite this article: |
ZHOU Yanqing,CHEN Yang. Research on the lightning intruding surge protection for 500kV substation[J]. Electrical Engineering, 2021, 22(3): 104-108.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2021/V22/I3/104
|
[1] 郭蕾, 古维富, 刘彬, 等. 杆塔接地装置的冲击阻抗建模及应用[J]. 电工技术学报, 2020, 35(10): 2239-2247. [2] 张恒志, 扎西曲达, 杨浩, 等. 西藏电网220kV线路雷害故障及防雷措施分析[J]. 电气技术, 2020, 21(4): 122-124. [3] 周欣佳, 蒋传文. 电气几何模型对500kV变电站雷电侵入波风险评估的影响[J]. 电气技术, 2016, 17(12): 1-4, 10. [4] 交流电气装置的过电压保护和绝缘配合设计规范:GB/T 50064—2014[S]. 2014. [5] 李福寿. 电力系统过电压计算[M]. 北京: 水利电力出版社, 1988. [6] 方雅琪, 王力农, 李瑞, 等. 高海拔带电作业间隙操作冲击放电特性及放电电压校正[J]. 电工技术学报, 2020, 35(12): 2681-2688. [7] 邱玉成, 李东辉. 基于波动方程解的结构的感应过电压计算与仿真[J]. 电气技术, 2020, 21(1): 31-36. [8] HARA T, YAMAMOTO O.Modeling of a transmission tower for lightning-surge analysis[J]. IEEE Transa- ctions on Power Delivery, 1996, 143(3): 283-289. [9] 金长宏. 雷电侵入波对变电站安全运行的影响及防护技术研究[J]. 河北企业, 2017(7): 199-200. |
|
|
|