Research and design of a test device for insulation selection of DC system in the transformer substation |
Mao Yan, Feng Cancheng |
Zhongshan Power Supply Bureau of Guangdong Power Grid Company, Zhongshan, Guangdong 528400 |
|
|
Abstract DC system is an important part of the safe operation of substation. The insulation selection test of dc system in transformer substation is an important part of the dc test, which can effectively verify that the insulation monitoring device installed in the dc system can alarm the reduced insulation dc load branch accurately when the insulation of the dc load branch is reduced. By designing simple and reasonable control circuit, ground busbar selection is realized by using change-over switch, and by grounding resistance adjustment and leakage current sensor wire clamp design, it is possible to improve the efficiency of transformer substation dc system insulation line selection test, reduce the risk of mistakenly touching the dc bus during the test, and achieve the ultimate goal of man-machine efficacy.
|
Received: 12 May 2018
Published: 16 November 2018
|
|
|
|
Cite this article: |
Mao Yan,Feng Cancheng. Research and design of a test device for insulation selection of DC system in the transformer substation[J]. Electrical Engineering, 2018, 19(11): 88-90.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2018/V19/I11/88
|
[1] 中国南方电网有限责任公司企业标准: 变电站直流电源系统技术规范. Q/CSG1203003—2013. 广州: 南方电网有限责任公司, 2013. [2] 邢春江. 变电站直流系统浅析[J]. 山东工业技术, 2015(7): 191. [3] 刘畅生, 王博一, 王家荣. 电源集成电路实用速查手册[M]. 北京: 中国电力出版社, 2010. [4] 毛焱, 黄永东. 一种在线式整组蓄电池维护装置的研究与设计[J]. 电气技术, 2015, 16(1): 68-70. [5] 董升, 陈文通, 郑晓东, 等. 一起直流系统母线绝缘下降故障实例分析[J]. 电气技术, 2015, 16(3): 97-99. [6] 张勋, 李刚. 变电站直流系统绝缘检测方法研究[J]. 电气技术, 2016, 17(10): 69-73. [7] Monk S.著, 孙宇, 译. 创客电子电子制作DIY指南[M]. 北京: 人民邮电出版社, 2016. [8] 曲学基, 曲敬铠, 于明杨. 电力电子元器件应用手册[M]. 北京: 人民邮电出版社, 2017. [9] 国网黑龙江省电力有限公司运维检修部. 变电站直流电源系统全过程精益化管理[M]. 北京: 中国电力出版社, 2017. [10] 广东电网公司东莞供电局. 变电站直流系统典型故障分析[M]. 北京: 中国电力出版社, 2014. |
|
|
|