Abstract Separable connectors are frequently equipped in 10~35kV MV power distribution systems. And the quality control is really important for them. This paper focuses on the commissioning test technology for them after installation, such as installation technology knowhow and commissioning test requirements. A practical tooling solution is proposed for application in commissioning tests, which enables the cable connectors to be effectively tested after installation. So, it becomes easier to check out electrical defects after installation and to avoid test failures due to improper installation.
|
Received: 21 January 2019
Published: 12 September 2019
|
|
|
|
[1] 陈添旭. 35kV屏蔽型可分离连接器在小型化配电设备上的应用[J]. 电气技术, 2013, 14(11): 71-73. [2] 韩云. 40.5kV带开关电缆分支箱结构优化及电场分析[J]. 电气技术, 2016, 17(10): 65-68, 73. [3] EN 50180: Bushings above 1kV up to 52kV and from 250A to 3, 15kA for liquid filled transformers[S]. [4] EN 50181: Plug-in type bushings above 1kV up to 52kV and from 250A to 2, 50kA for equipment other than liquid filled transformers[S]. [5] IEEE 386: IEEE standard for separable insulated connector systems for power distribution systems above 600V[S]. [6] 相晓鹏, 张力强, 常尼亚.某供电区10kV环网柜电缆肘型头故障分析[J]. 山西电力, 2010(6): 24-25. [7] 潘天晟. 现代有轨电车中压环网供电方式的研究[J]. 电气技术, 2018, 19(8): 195-198. [8] 钟志毅, 欧景茹, 郭铁军. 交联聚乙烯绝缘电力电缆交流耐压试验研究[J]. 电网技术, 2007(S1): 108-111. [9] IEC 60502-2:2014. Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1,2kV) up to 30kV [10] IEC 60840:2011. Power cables with extruded insulation and their accessories for rated voltages above 30kV (Um=36kV) up to 150kV (Um=170kV)- test methods and requirements[S]. [11] GB 50150—2016. 电气装置安装工程电气设备交接试验标准[S]. [12] GB/T 12706—2008. 额定电压1kV(Um=1.2kV)到35kV [13] DL/T1253—2013. 电力电缆线路运行规程[S]. [14] Q/GDW 11316—2014. 电力电缆线路试验规程[S]. [15] 左婧. 10kV 630A电缆快速接头装置的研究与应用[J]. 电气技术, 2014, 15(12): 92-94. [16] 杨帆, 杨旗, 程鹏, 等. 电缆接头内部气隙放电缺陷下的绝缘劣化程度表征方法[J]. 电工技术学报, 2017, 32(2): 24-32. [17] 周凯, 吴科, 万利, 等. 无机纳米颗粒抑制中压电缆终端气隙缺陷局部放电的有效性[J]. 电工技术学报, 2016, 31(22): 230-238. [18] 卓金玉. 电力电缆终端结构中的应力锥电场数值分析和模拟实验研究[J]. 电工技术学报, 2000(2): 15-19. [19] 庞凯歌, 牛哲荟, 王永亮, 等. 双通套管电场仿真及结构优化研究[J]. 电器与能效管理技术, 2018(19): 22-25. [20] 陈四卯, 赵淑欣, 李中海. 10kV电缆分接箱的选型及使用[J]. 河北工程技术高等专科学校学报, 2008(4): 48-50. |
|
|
|