Study on the measurement method of volume resistivity of buffer material for high voltage cable |
Huang Yu, Wu Changshun, Sun Li |
Shanghai Intelligent Service and Technology Co., Ltd, Shanghai 201206 |
|
|
Abstract This paper analyzes the measurement and calculation method of volume resistivity of buffer layer material in JB/T 10259—2014 standard firstly, and then combined with the actual construction of high-voltage cable and the material characteristics of water-resistant buffer layer of high-voltage cable, reveals the volume resistivity test method of buffer layer in JB/T 10259—2014 standard can not reflect the actual situation of buffer layer in high-voltage cable in terms of contact area and applied load. A large number of test data show that the volume resistivity of buffer layer material is closely related to the pressure and electrode contact area. In order to measure the volume resistivity of buffer layer material more accurately, the test method which can reflect the actual contact mode between corrugated aluminum sheath and buffer layer is necessary.
|
Received: 09 July 2020
|
|
|
|
Cite this article: |
Huang Yu,Wu Changshun,Sun Li. Study on the measurement method of volume resistivity of buffer material for high voltage cable[J]. Electrical Engineering, 2020, 21(10): 123-126.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2020/V21/I10/123
|
[1] 黄宇, 尹毅, 吴长顺. 高压电缆阻水缓冲层电性能研究[J]. 电线电缆, 2018(6): 6-9, 19. [2] 杨娟, 张峰, 王福志. 高压电力电缆阻水结构研究与分析[J]. 电线电缆, 2010(3): 22-24, 27. [3] 赵健康, 樊友兵. 高压电缆缓冲层的设计与工艺研究[J]. 电线电缆, 2010(3): 17-21. [4] 汪传斌, 金海云. 高压XLPE绝缘电力电缆缓冲层与金属护层结构设计仿真计算与优化[J]. 电线电缆, 2018(3): 6-12, 16. [5] 杨帆, 朱宁西, 刘晓东, 等. 基于阻抗评估电缆缓冲层间隙状况的实验与分析[J]. 广东电力, 2018, 31(12): 93-98. [6] 中华人民共和国机械工业部. JB/T 10259—2014. 电缆和光缆用阻水带[S]. 北京: 机械工业出版社, 2014. [7] 高压电缆缓冲层特性研究报告[Z].高压电缆缓冲层特性研究报告[Z]. 上海缆慧检测技术有限公司, 2019. [8] 中华人民共和国国家标准. GB/T 11017.2—2014. 额定电压110kV(Um=126kV)交联聚乙烯绝缘电力电缆及其附件第2部分: 电缆[S]. 北京: 中国标准出版社, 2014. [9] 中华人民共和国国家标准. GB/T 18890.2—2015. 额定电压220kV(Um=252kV)交联聚乙烯绝缘电力电缆及其附件第2部分: 电缆[S]. 北京: 中国标准出版社, 2015. [10] 中国标准化协会. T/CAS 374—2019. 额定电压26/35kV以上挤包绝缘电力电缆用半导电缓冲层材料[S]. 北京: 中国标准化协会, 2019. |
|
|
|