Reliability improvement of station traveling wave fault location based on protection information |
WU Zhanguo1, QIAO Yufeng1, LI Huiyong2, XU Xiaochun3, HUANG Tao3 |
1. Inner Mongolia Electric Power Co., Ltd, Hohhot 010020; 2. Ulanqab Power Supply Bureau, Inner Mongolia Electric Power Co., Ltd, Ulanqab, Inner Mongolia 012000; 3. NR Electric Co., Ltd, Nanjing 211102 |
|
|
Abstract Traveling wave fault location (TWFL) has the advantages of high accuracy and little influence by the system operation mode, but the independent TWFL is vulnerable to noise, which leads to a bad reliability. Traditional AC line protection technology is mature and has strong anti-interference ability and high reliability. It is a feasible technical route to improve the TWFL reliability by using protection information. In this paper, based on the integration of protection and TWFL, the problems of independent TWFL and the information interaction technology between protection and TWFL are analyzed. Combined with the protection related information, detailed technical schemes to improve the reliability of station TWFL are presented, which include fault location start-up, synchronous phase selection and fault location result screening. Based on the above technologies, the software and hardware test platform are built, and the experimental results verifiy the effectiveness of the proposed schemes.
|
Received: 25 January 2021
|
|
|
|
Cite this article: |
WU Zhanguo,QIAO Yufeng,LI Huiyong等. Reliability improvement of station traveling wave fault location based on protection information[J]. Electrical Engineering, 2021, 22(8): 62-68.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2021/V22/I8/62
|
[1] 刘树鑫, 卓裕, 李津, 等. 基于微型同步向量单元数据的配电线路故障测距方法[J]. 电气技术, 2020, 21(10): 63-70. [2] 张希鹏, 邰能灵, 郑晓冬, 等. 基于WEMTR的柔性直流输电线路故障测距[J]. 电工技术学报, 2019, 34(3): 589-598. [3] 谈浩, 徐晓春, 赵青春, 等. 两侧时钟同步校验及不依赖对时的行波测距[J]. 电气技术, 2019, 20(1): 80-83. [4] 覃剑, 葛维春, 邱金辉, 等. 影响输电线路行波测距精度的主要因素分析[J]. 电网技术, 2007, 31(2): 28-38. [5] 侯丽钢, 汤向华, 江辉, 等. 应用于含有线-缆混合线路配电网的行波故障测距新方法[J]. 电力工程技术, 2019, 38(2): 111-116. [6] 周鲁天, 梁睿, 彭楠, 等. 基于ARIMA的矿山电网故障暂态行波波头辨识及故障测距[J]. 电力自动化设备, 2020, 40(6): 177-183. [7] 陈乐, 彭咏泉, 林湘宁, 等. 面向接地故障辨识的半波长线路测距式超高速就地主保护新原理研究[J]. 电工技术学报, 2019, 34(24): 5234-5243. [8] 付华, 吴赛, 徐耀松, 等. 基于VMD和广义S变换的HVDC线路故障定位[J]. 电力系统保护与控制, 2020, 48(4): 125-133. [9] 丁晓兵, 陈玉林, 史泽兵, 等. 线路保护行波测距一体化装置设计与关键技术研究[J]. 南方电网技术, 2017, 11(6): 57-62. [10] 高小全, 刘宏君, 俞伟国, 等. 一种应用于线路保护装置的嵌入式行波测距方法[J]. 浙江电力, 2020, 39(3): 1-7. [11] 周象贤, 王少华, 童杭伟, 等. 高压输电线路多落点雷击故障分析方法及应用[J]. 电瓷避雷器, 2018(4): 184-187. |
|
|
|