PEVs and Interruptible Loads for Frequency Regulation |
Liu Baoping, Yang Hongming |
Hunan Province Key Laboratory of Smart Grids Operation and Control, Changsha University of Science and Technology, Changsha 410114 |
|
|
Abstract Due to the randomness of the renewable energy, high penetration of wind and photovoltaic power generation will bring a series of problems such as frequency fluctuations. A large number of Plug-in electric vehicles (PEVs) and controllable loads have been shifting into focus for this. A dynamic vehicle-to-grid (V2G) model with feedback control is proposed by considering the battery charging/discharging characteristics and the dynamic model of frequency regulation with PEVs and controllable loads for a single area is established. Simulation results demonstrate that the application of PEVs and controllable loads can relief the frequency refutation due to the randomness of renewable energy sources.
|
Received: 26 June 2014
|
|
|
|
[1]BOULAXIS N G, PAPATHAMTSSIOU S A, Papadopoulos MP. Wind turbine effect on the voltage profile of distribution networks[J]. Renewable Energy, 2002, 25(3): 401-415. [3]LAWRENCE E O, HEFFNER G, GOLDMAN C, KINTNER-MEYER M, KIRBY B.Technical Appendix: Market Descriptions, 2007. [4] KEMPTON W, DHANJU A. Electric vehicles with V2G: storage for large-scale wind power[J]. Windtech International, 2006, 2(5): 18-21. [5] KEMPTON W, LETENDRE S. Electric vehicles as a new power source for electric utilities[J]. Transportation Research (Part D), 1997, 2(3): 157-175. [6] KEMPTON W, TOMIC J. Vehicle-to-grid power implementation: from stabilizing the grid to supporting large-scale renewable energy[J]. Journal of Power Sources, 2005, 144(1): 280-294. [7] KEMPTON W, DHANJU A. Electric vehicles with V2G: storage for large-scale wind power[J]. Windtech International, 2006, 2:18–21. [8] KONDOH J. Autonomous frequency regulation by controllable loads to increase acceptable wind power generation [J]. Wind Energy, 2010, 13(6): 529–541. [9] PILLAI J R, BAK-JENSEN B. Integration of Vehicle- to-Grid in the Western Danish power system[J]. IEEE Transaction on Sustainable Energy, 2011, 2(1): 12-19. [10] SALAMEH Z M, CASACCA M A, LYNCH W A. A mathematical model for lead-acid batteries [J]. IEEE Trans on Energy Conversion, 1992, 7(1): 93-98. [11] LU C F, LIU C C, WU C J. Effect of battery energy storage system on load frequency control considering governor deadband and generation rate constraint[J]. IEEE Trans. on Energy Conversion, 1995, 10(3): 555-561. [12] Manual of Electric Water Heaters—Plan, Design, & Execution. Extra Issue of Amenity & Electri? cation, Japan Industrial Publishing Co, 1999-3. [13] Advanced Transport Systems Ltd. "ULTra PRT, " Jun. 2010. [OL]. Available: http://www.ultraprt.com/. |
|
|
|