Key test methods for alternating current and direct current systems of offshore converter stations |
QIAO Mei1, JIANG Haitao1, DING Haifeng2 |
1. China Guangdong Nuclear New Energy Nantong Co., Ltd, Nantong, Jiangsu 226400; 2. China Resources Guangdong New Energy Co., Ltd, Guangzhou 511500 |
|
|
Abstract With the development of flexible DC technology in China, the installed capacity of offshore wind power continues to increase. The offshore flexible DC transmission voltage has reached ±400kV, marking the first application of offshore converter station successful. By studying the tests of the ±400kV flexible DC transmission demonstration project for wind power in Rudong, Jiangsu, the testing method for the offshore converter station system is proposed to lay a technical foundation for the subsequent application of offshore wind DC transmission projects.
|
Received: 04 July 2023
|
|
|
|
Cite this article: |
QIAO Mei,JIANG Haitao,DING Haifeng. Key test methods for alternating current and direct current systems of offshore converter stations[J]. Electrical Engineering, 2023, 24(11): 18-27.
|
|
|
|
URL: |
http://dqjs.cesmedia.cn/EN/Y2023/V24/I11/18
|
[1] 舒印彪. 中国直流输电的现状及展望[J]. 高电压技术, 2004, 30(11): 1-2. [2] 袁清云. 特高压直流输电技术现状及在我国的应用前景[J]. 电网技术, 2005, 29(14): 1-3. [3] 陶瑜, 龙英, 韩伟. 高压直流输电控制保护技术的发展与现状[J]. 高电压技术, 2004, 30(11): 8-10. [4] 赵畹君. 高压直流输电工程技术[M]. 北京: 中国电力出版社, 2004. [5] 王雅婷, 张一驰, 郭小江, 等. ±1100kV特高压直流送受端接入系统方案研究[J]. 电网技术, 2016, 40(7): 1927-1933. [6] 熊银武, 钟昆禹, 王林, 等. 柔性直流输电换流阀型式试验补能电源研究[J]. 电气技术, 2020, 21(1): 37-40. [7] 刘振亚. 特高压直流输电理论[M]. 北京: 中国电力出版社, 2009. [8] 梁营玉, 许冠军, 李武林, 等. 柔性直流换流站对传统选相方法的影响分析及对策[J]. 电工技术学报, 2020, 35(1): 201-212. [9] 庞龙英, 马玉龙, 曾南超, 等. RTDS应用于直流控制保护系统的仿真试验[J]. 高电压技术, 2005, 31(8): 56-58. [10] 郭绯阳, 张涛, 吴鑫, 等. ±800kV特高压直流输电换流阀核相试验[J]. 电气技术, 2021, 22(4): 63-68. [11] 洪潮. 云广±800kV直流输电工程系统试验(英文)[J].南方电网技术, 2010, 4(2): 7-14. [12] 李建国, 刘文华, 王久和, 等. 基于LCC和双钳位MMC混联高压直流输电的实验[J]. 电工技术学报, 2018, 33(16): 3677-3685. [13] 杨万开, 印永华, 班连庚, 等. ±1100kV特高压直流系统试验方案研究[J]. 电网技术, 2015, 39(10): 2815-2821. |
|
|
|